Light on / off when closed
=> (see page 2, point 12)
Dimming in the closed state
=> (see page 2, point 11)
Test operation in the closed condition to enable
Disable the test mode: press reset
Resetting when closed
The lighting relay is switched off, i.e. opened and the follow-up times
reset.
Permanent protection against sabotage
This function blocks the unit permanently (green LED is illuminated). This
operating mode can only be activated during the period of 5 seconds
after pressing the “lock“ button. This status will only permit actuating the
function “Light on/Light off”. The procedure for leaving this mode is as
follows:
1. Switch off the current
2. Apply current for 31 - 59 seconds
3. Switch of the current again
4. Apply current
5. Open detector
Dim in the open state
To set a target value, proceed as follows (example workplace):Place one
lux meter flat on the desk. Set the light. With the help of remote control
IR-PD4-DIM by pressing the buttons „max“ or „min“ as necessary. Wait
until the desired light level is reached.
Confirmation by the preset value
Light during the initialization
The light is on by default in the initialization time.
On / off with the „Light“ button during Initialization. The final condition
is then active.
Orientation light ON / OFF when open
Note:
Also during the orientation phase of the light constant light control is
active: With sufficient brightness is <20% dimmed and turned off the lights
if necessary.
Installation and Operating Instruction for
B.E.G.
-
Occupancy detectors
PD4-M-DIM-HVAC-FC
1. Mounting preparations
Work on the 230 V mains supply
may only be carried out by quali
-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrical regulations.
Disconnect supply before installing!
The device is not suited for safe
disconnection of the mains supply.
When in Master/Slave mode of op-
eration, the Master-appliance must
always be installed at the location
where there is least daylight.
LUXOMAT
®
PD4-M-DIM-HVAC
GB
4. DIP switch functions
DIP-
switch
ON
OFF
1
Semi automatic mode Fully automatic mode
2
LED OFF
LED ON
3
Corridor mode
Standard mode
Corridor function:
After deactivation by an external push
button, the detector switches off and returns to automatic
mode after 5 sec.
3. Position DIP-switches
7. Option:
Wall bracket for remote
control IR-PD-DIM-HKL
IR-PD-DIM-HKL
max
50
Lux
1500
Lux
ON
OFF
t < 5 s
8. Settings by remote control
9.
Explanation of the remote control button functions
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
5. Putting into operation / Settings
Self test cycle
After an initial 60-second self-test cycle, the
LUXOMAT
®
PD4-M-DIM-HVAC is ready
for operation.
Follow-up time for light control
The time can be set infinitely variably at between 1 and 30 minutes.
Symbol
TEST
: Test mode
Every movement switches on the light for a period of 1 second, switching
it off for a period of 2 seconds after that regardless of the level of
brightness
Twilight-switch for light control (relay 1)
The switch-on value for the light can be set at between 10 and 2000 Lux.
Using the rotary control, the luminance set points can be set as desired.
Symbol
:
Night-time operation
Symbol
:
Daytime/Night-time operation
Orientation lighting
This rotary controller serves to determine the working time of the
orientation lighting (fixed to 20 %).
“ON” for permanent orientation lighting.
“OFF” for deactiviation of orientation lighting.
9s
2s
LED ON
LED OFF
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
60
5
10
30
50
ON
OFF
6. Settings carried out using remote
control (optional)
Remote control LUXOMAT
®
IR-PDim
1. Check Battery:
Open battery compartment by pressing the plastic
springs together and removing the battery-holder.
2. IMPORTANT
Please pay attention, that the setting is Potentiometer
1 at “TEST” and Potentiometer 2 not at
“SUN”. All values which have been programmed
using the remote control will be deleted in the
event of power failure in the position “TEST/
SUN”. Please switch Potentiometer 2 over to
“MOON” or any other value.
Caution:
Settings with remote control supersede the settings
by courtesy of potentiometers.
1
1
2
2
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
25 22
18
16
10
3
1
TEST
6
30
R1
2000
1200
600
200
40
Flush Ceiling
1
2
3
ON
OFF
DIP
A circular opening of
diameter 68 mm must first
of all be produced in the
ceiling.
Having connected up the
cables in accordance with
regulations, the detector is
inserted into the opening
as shown in the drawing
opposite and fixed into
position with the assis-
tance of the spring clip.
2. Installation of the LUXOMAT
®
PD4-M-DIM-HVAC-FC
The DIP settings are enabled again by
• Adjusting the DIP switches when closed
• Reset with test sun setting at the potentiometers
• Reset when open
Function LEDs OFF:
In the open state and in test mode, the
LEDs are always ON.
DIP
OFF
ON
1
2
3
Follow-up time for appliance-control
The time can be set infinitely variably at between 5
minutes and 120 minutes. After 15 minutes the switch-on
delay is activated. This is around 5min. If there are not
detected any further movements within this period, the
switch-on delay starts again.
Symbol :
Impulse = 2.5 sec.
Symbol
A
:
Alarm impulse = 2 sec.
Alarm impulse
In order to set off an alarm impulse, at least 3 move-
ments within 9sec. have to be detected.
Pulse spacing PD-Slave
2 or 9 seconds can be set for the pause between 2
pulses sent to the master. The setting can be made with
activated ( ) or deactivated ( ) LED indicator.
For devices with a separate slave input, 2 sec. can be
set.
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
The DIP switch settings are overriden using
the remote control.
Unlocking device – Activation of
the programming mode
Preset/user mode
=> (see page 2, point 11)
Resetting when-
open:
Deletes all
values set with
the remote con-
trol, light OFF.
Orientation lighting and its
follow-up time
Orientation lighting ON/OFF
20 % of the nominal light
or
Dimming of the lighting on the
desired luminance value
Luminance set point for constant
light control
50
Lux
to
1500
Lux
1
min
to
60
min
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
or
Automatic reading in the current light
value as new luminance set point
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
optional
optional
optional
Locking device – Exit programming
mode
Permanent protection against
sabotage
LED flashes
t < 5 sec.
Follow-up time Channel 1
1 - 30 min.
Follow-up time Channel 2 (HVAC)
5 - 60 min. or impulse
1
min
5
min
30
min
60
min
Fully automatic/semi automatic
mode => (see page 2, point10)
20 %
500
TEST
B.E.G.
LUXOMAT
®
IR-PD-DIM-HKL
750
1000
1500
50
100
250
RESET
5
min
10
min
15
min
1
min
OFF
ON
30
min
60
min
10
min
30
min
60
min
15
min
1
min
5
min
min
max
30
min
20%
In the initialization period
During initialization phase/self test cycle
Lights can be set to on or off status during initialization(60 Seconds) by
using INI OFF/ON mode.
max
50
Lux
1500
Lux
ON
OFF