LUXOMAT
®
LC-Click-N 140 / 200
GB
Installation and Operation Instruction motion detector
B.E.G.
–
LUXOMAT
®
LC-Click-N 140 and LC-Click-N 200
6. Mounting types
1) Wall mounting
3. Inserting of the connection cable
1) Cable entry points
2) Terminal markings
7. Putting into operation / Settings
Self test cycle
After mounting and connecting the 230 VAC supply volta-
ge, the LC-Click-N 140/200 runs a self testing unit. Then
the unit is ready for operation and the settings can be
made manually or with remote control.
2. Wall mounting
Mount the plug-in socket with two screws and
the enclosed seal rings on a firm base.
(Pay attention to inserting of the connection
cable, see point 3)
4. Sensor head optics
By swinging the sensor head horizontally
(ca. 90°) and vertically (ca. 85°) detection
area can be changed.
5. Exclude sources of interference
8. Range of Coverage
Walking Towards
Walking across
Anti-creep
1
Walking Towards
Walking across
Anti-creep
1) If possible mount unit on a safe place
(wall or ceiling mount)
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
3) Minimum distance to switched lighting,
frontally or laterally to device: 1 m
4) Never mount the connected lights below
the motion detector!
If necessary, the lens segment(s) corresponds
to unwanted detection zones may be masked
with the enclosed covers to reduce the field
of vision.
1
2
1
2
1
3
3
3
3
Follow-up time
4sec. ... 10Min.
Lux value
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching at
any brightness value)
1. Mounting preparations
1)
Caution: have all work involving the
230 V mains supply carried out by a
qualified electrician! Before starting
disconnect the mains! Please be aware,
that the LUXOMAT
®
LC-Click-N 140/200 is
not suitable as an intrusion detector, since
it is not equipped with a tamper contact.
2) Socket base corner mounting
The device is not suited for safe disconnection
of the mains supply.
Important:
The
LUXOMAT
®
LC-Click-N
140/200 has to be mounted in such a way,
that the adjusting elements / rotary regulators
are always pointed downward.
Caution:
Do not connect more than2
LUXOMAT
®
LC-Click-N in one circuit, to avoid any erroneous
switching.
1
2
2
1:4
1.
0.5
0.25
Futur
a Bo
ok 24Pt
> 1m
1000
40
10
130
2 Lux
4
sec
20
1.2
10
min
6
50
1000
40
10
130
2 Lux
4
sec
20
1.2
10
min
6
50
1
2
1
2