Product Overview
UL Installation Guide
Terminal Block
Baud Rates
Wire the Converter
1
3
2
4
Fiber
Connectors
Terminal
Blocks
LEDs
DIP Switch
Underwriters Laboratories Conditions of Acceptability –
When installed in the end-use equipment, consideration
should be given to the following:
1. The wiring terminals are suitable for factory wiring only.
2. This device is to be mounted in a suitable enclosure in
the end-product.
3. This device is suitable for operation at a maximum
surrounding air temperature as described in the
documentation.
4. These devices are intended for use in a pollution
degree 2 environment.
-Input Voltage: 10 – 30 VDC
- Input Power 4.2 Watts
- Wire Range: 12 – 24 AWG
- Tightening Torque: 4 kgf-cm
- Temperature rating of filed installed conductors is
105 C minimum, sized for 60 C ampacity.
- Use copper wire only
- Maximum surrounding ambient air temperature
80 C
RS-232
RS-485 2 Wire
RS-422/RS-485 4 Wire
Fiber Optic
Terminal
Signal
A
RS-232 RD (OUTPUT)
B
GND
C
GND
D
RS-232 TD (INPUT)
E
NOT CONNECTED
F
+10 TO 30 VDC
G
RS-422/485 TDA ( - ) / DATA A ( - )
H
RS-422/485 TDB (+) / DATA B (+)
J
+10 TO 30 VDC
K
RS-422/485 RDA ( - ) / DATA A ( - )
L
RS-422/485 RDB (+) / DATA B (+)
Baud
1
2
3
4
5
4800
OFF
OFF
OFF
OFF
ON
9600
OFF
OFF
OFF
ON
OFF
19.2K
OFF
OFF
ON
OFF
OFF
38.4K
OFF
ON
OFF
OFF
OFF
57.6K
ON
OFF
OFF
OFF
OFF
76.8K
ON
OFF
ON
ON
OFF
115.2K
ON
ON
ON
OFF
OFF