Azonix Barracuda 15

DRAFT - 16 September 2014

Azonix Barracuda 15”

Rugged Zone 2 Workstation

September 2014
INM 19-102156 A

Instruction Manual

HMI and Visualisation

Summary of Contents for Barracuda 15"

Page 1: ...DRAFT 16 September 2014 Azonix Barracuda 15 Rugged Zone 2 Workstation September 2014 INM 19 102156 A Instruction Manual HMI and Visualisation...

Page 2: ...nd does not convey any license under the patent rights of Azonix nor the rights of others All trademarks registered trademarks and trade names used in this user s manual are the property of their resp...

Page 3: ...Workstation 12 3 1 5 Top View Workstation 12 3 1 6 Sun Shade and Yoke Custom Option Only 13 14 3 2 Connectors 15 3 2 1 Workstation 15 3 2 2 Connector Pinouts 16 17 3 3 Front Panel 18 3 4 Specificatio...

Page 4: ...ess Map 41 9 2 System Memory Mapping 42 9 3 Interrupt Assignments 42 10 Flat Panel Display Characteristics 43 10 1 Overview 44 11 Troubleshooting and Quick Reference Guide 44 45 12 Resistive Touchscre...

Page 5: ...ack please send us a message using ourWeb site www azonix com under Technical Support Detail any errors you find We will correct the errors or problems as soon as possible Thank you 1 4 Trademarks Bar...

Page 6: ...ements when notified by Buyer during a period of twelve 12 months after shipment by Seller except for spare parts which are warranted for ninety 90 days after shipment To invoke the warranty set forth...

Page 7: ...O ANY DEFECT IN ANY PRODUCTS INCLUDING WITHOUT LIMITATION ANY A IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR USE OR FITNESS FOR A PARTICULAR PURPOSE B ANY IMPLIED WARRANTY ARISING FROM COURSE OF...

Page 8: ...hether the unit is Warranty or Non Warranty If the unit is Warranty no method of payment will need to be entered Please enter all data requested When the process has been completed you will receive a...

Page 9: ...un risque de l sions corporelles contre les risques lectriques et explique comment viter le probl me ALTERNATING CURRENT MISE LA TERRE The Protective Conductor Terminal Earth Ground symbol indicates...

Page 10: ...luding HAZLOC areas the Barracuda offers ultra reliable operation backed by hundreds of hours of testing and full compliance with multiple Military and HAZLOC standards The workstation version integra...

Page 11: ...stic fiber drivers EoPOF Second serial port Horn driver board AC source DC 24V Heaters for 40C operation DC source DC 24V Heaters for 40C operation DC DC power supply 9 36VDC Larger capacity 1 8 SSDs...

Page 12: ...r s instruction manual may cause harmful interference with radio communications This equipment has been tested and found to be within the limits for a Class A digital device pursuant to Part15 of the...

Page 13: ...DRAFT 16 September 2014 9 INM 19 102156 A 3 INTRODUCTION 3 1 Product Description 3 1 1 Front View and Layout Dimensions...

Page 14: ...DRAFT 16 September 2014 10 INM 19 102156 A 3 1 2 Side View Workstation...

Page 15: ...DRAFT 16 September 2014 11 INM 19 102156 A Rear View Workstation 3 1 3 Rear View Workstation...

Page 16: ...DRAFT 16 September 2014 12 INM 19 102156 A 3 1 4 Bottom View Workstation 3 1 5 Top View Workstation...

Page 17: ...DRAFT 16 September 2014 13 INM 19 102156 A 3 1 6 Sun Shade andYoke Custom Option Only Preliminary Views...

Page 18: ...DRAFT 16 September 2014 14 INM 19 102156 A Preliminary Views...

Page 19: ...rk Thoroughly read the Precautions section before connecting any external peripheral devices to your system Make sure the unit is turned Off before connecting any cables After you make the connections...

Page 20: ...Pin Name Description 1 VCC 5 VDC 2 D Data 3 D Data 4 GND Ground Pin Name Description 1 TX Transfer Data 2 TX Transfer Data 3 RX Receive Data 4 n c Not connected 5 n c Not connected 6 RX Receive Data...

Page 21: ...a E CTS Clear to send F TXD Transmit data G ISO24 Horn plus H DTR Data terminal ready I GND Signal ground J ISO Ret Horn minus Amphenol I O Circular Conn RS232 RS422 RS485 Comments A DSR RTS B DCD TX...

Page 22: ...A 3 3 Front Panel LEDs Icon Color Description Green Power on LED Yellow HDD Active LED Orange Heater ON LED Blue LCD Touch OFF LED Buttons Icon Description LCD Touch On Off Button Brightness Up Down...

Page 23: ...DS internal connection supporting a single 18 24bit dual channel LVDS panel Supports 24 bit dual channel LVDS panel Ethernet Function 1x Intel 82583V PCI Express Gigabit Ethernet Audio Function Sound...

Page 24: ...Panel power consumption 1 35 Typ W 14 Weight 1350g g 3 3 3 Power Supply Specifications The Barracuda is supplied with a high efficiency 100W switching power supply unit which is EN61000 3 2 3 complian...

Page 25: ...h 4 84 Unit Weight 20 lbs without power supply 23 5 lbs with power supply 3 3 5 Installation Certification Requirements Requirements Pollution Degree 2 Installation Category II Max Operating Altitude...

Page 26: ...overall life span of any electronic device is shortened when operated at its highest rated temperature Leave all covers in place at all times during operation The covers protect the user against high...

Page 27: ...AC power cable s copper core cross section should be at least 1 5mm2 per wire ALTERNATING CURRENT MISE LA TERRE To prevent electrical shock the Safety Earth Ground location on the rear as indicated b...

Page 28: ...onnexion 1 Before installing the unit bench test by connecting all data and power connections Turn On the power After the adjustments have been made turn Off the power and disconnect the cabling 2 Car...

Page 29: ...the system unit first Then connect the other end into a grounded AC power source 3 After the system is connected to a power source apply power to the system using the user accessible breaker press the...

Page 30: ...em by pressing the Ctrl Alt Del keys You will want to enter the BIOS Setup Utility for the following reasons Changing components for example if you add a hard disk or memory If you do not run the Setu...

Page 31: ...ly F7 Key Load the default F8 Key Reserved F9 Key Reserved F10 Key Save all the CMOS changes Main menu only 4 3 Obtaining Help Press the F1 key to display a small Help screen that describes the approp...

Page 32: ...a Associates Limited UK Figure 1 or Yoda Alarm family devices for example YO5 Figure 2 The IS horns can only be connected to the Barracuda if the internal Horn Board option is purchased Please contact...

Page 33: ...ng the horn upwards will cause the horn to become clogged with water or dust effecting performance NOTE Local codes of practice may override certain installation aspects NOTE Installation in accordanc...

Page 34: ...ore wire can be used to the maximum length allowed 138 meters 448 feet or by calculation for the selected cable 3 The connection cable capacitance plus any other capacitance must not exceed 83nF Co 83...

Page 35: ...0mW Ci 0 Li 0 Ingress protection IP66 with a sealed cable gland 48 programmable alarm tones Figure 4 Beka Horn internal power connection terminal Yoda hornYO5 ISC T4 NOTE Example only Consult manufact...

Page 36: ...e below Figure 7 Connection to Barracuda 15 both versions Pin Name Description A DSR Data set ready B DCD Data carrier detect C RTS Ready to send D RXD Receive data E CTS Clear to send F TXD Transmit...

Page 37: ...rly connected to a grounded outlet and is receiving power 2 The system begins the POST test This test verifies that the system memory systeboard hard disk drive and any other external peripheral devic...

Page 38: ...e component activated during that step may be faulty Contact Azonix technical support for help or advice if the Start up sequence cannot be entirely executed 8 If the system issues any error messages...

Page 39: ...dim screen Activated screensaver Disable screen saver Brightness set too low Turn up the Brightness control Display disabled Push the LCD ON blue Button Display not turned On Push On the power switch...

Page 40: ...r An error message may be followed by a prompt to press F1 to continue or to press Del to enter Setup Each error message is accompanied by an explanation or a solution Refer to your system board manua...

Page 41: ...onflict between a software application and your device drivers Is there an Interrupt conflict between your devices Does your software program require any extra hardware devices Are there any special m...

Page 42: ...ver usually COM1 If the mouse cursor does not move or it is moving erratically remove the mouse ball and clean it and the rollers Use a cotton swab moistened with surgical alcohol to clean the rollers...

Page 43: ...not to scratch or press hard with any object on the touch screen surface By doing so you may easily damage the PET surface Shade the display from direct sunlight To protect your display against burn...

Page 44: ...ng the Barracuda Casing Use the following procedure to clean the Barracuda CAUTION ATTENTION Before cleaning the Barracuda make sure the power is turned Off and the power cord is disconnected otherwis...

Page 45: ...errupt Controller 1 040h 05Fh SystemTimer 060h 06Fh Keyboard Controller 070h 07Fh RealTime Clock NMI 080h 09Fh DMA Page Register 0A0h 0BFh Interrupt Controller 2 0F0h DMA Controller 2 0F1h Clear Math...

Page 46: ...0 FFFDFFFF System Memory FFFE0000 FFFFFFFF 128K On Board BIOS ROM 8 3 Interrupt Assignments There are a total of 15 IRQ lines available on the system board Peripheral devices use interrupt request lin...

Page 47: ...reens and the manufacturer s actual ability to produce a product of near perfect quality at a reasonable price This has driven the AM LCD manufacturers to write detailed specification documents defini...

Page 48: ...ts or inverter are not working Return for factory repair Check that the Brightness Control is at the appropriate position not at the minimum Solid white screen No Video Video signal not supplied to LC...

Page 49: ...sh or HDD Verify no external boot device is connected Return for factory repair Barracuda is on but it is frozen My cursor is stuck on the hourglass and won t let me do anything Simultaneously press C...

Page 50: ...citance touch sensors colloquially called Pcap or ProCap touchscreens embody the very latest features available for rugged touch sensors being constructed from solid strengthened glass sensing through...

Page 51: ...ld be protected from the possibility of spraying water from a process or activity where this is possible While the unit is switched off the Barracuda fitted with a Pcap touchscreen can be washed down...

Page 52: ...FT 16 September 2014 48 INM 19 102156 A 13 Certificates The Barracuda Gen2 15 Workstation is certified for Hazardous Area usage according to the following certificates 13 1 ATEX Certificate of Conform...

Page 53: ...DRAFT 16 September 2014 49 INM 19 102156 A...

Page 54: ...DRAFT 16 September 2014 50 INM 19 102156 A...

Page 55: ...DRAFT 16 September 2014 51 INM 19 102156 A...

Page 56: ...DRAFT 16 September 2014 52 INM 19 102156 A 13 2 IECEx Certificate of Conformity...

Page 57: ...DRAFT 16 September 2014 53 INM 19 102156 A...

Page 58: ...DRAFT 16 September 2014 54 INM 19 102156 A...

Page 59: ...DRAFT 16 September 2014 55 INM 19 102156 A...

Page 60: ...DRAFT 16 September 2014 56 INM 19 102156 A 13 3 AEx Certificate of Compliance...

Page 61: ...DRAFT 16 September 2014 57 INM 19 102156 A...

Page 62: ...DRAFT 16 September 2014 58 INM 19 102156 A...

Page 63: ...DRAFT 16 September 2014 59 INM 19 102156 A 13 4 AEx Certificate of Compliance...

Page 64: ...DRAFT 16 September 2014 60 INM 19 102156 A...

Page 65: ...DRAFT 16 September 2014 61 INM 19 102156 A 14 Document Revision History Revision Date Edited by Changes 1 0 26 March 2014 KAG First draft A 25 July 2014 JMG Release...

Page 66: ...puram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via A Meucci 10 I 20094 Corsico MI Italy Tel 39 0...