Chapter 5. ADVANCED OPERATION
Device information display item
No.
Display
Item
Description
Setting Range and
Description
Related
Function Setup
Remarks
1
Ga5
Gas type
0 : Conversion factor for
each gas type set by the
user
9 : Hydrogen
10 : Helium
C-
18
,
C-26
2
f.5Cl
Full-scale
flow rate
(10 to 100 % of standard
range)
C-
18
,
C-24
C-25
,
C-26
Unit: L/min(standard) ("mL/
min(standard)" on the
MQV9020/9050)
3
5.deG
Reference
temperature
0 to 35
C-
19
Unit: °C
4
c.ad5
*
Communications
address
0 to 127
C-30
"0" means communications
function disabled.
* Only for models with RS-485 communications.