Operation using the data setting device
Model MCB10A 5-17
Step
Procedure
Screen
5
Press the
h
or
i
key to select ON or OFF.
20.0 %
* SPIKE CUT
ON
6
Press the
g
key to move the cursor to the
position under *.
Press the MODE key to return to the
MEASURING MODE and save data.
20.0 %
* SPIKE CUT
OFF
CAUTION
You have only ten minutes to return to MEASURING MODE to save the new
value before the system resets it to the previously saved value.
5-5-6 : Setting moving average processing
This function is used to carry out the moving average processing of the measured
flow rate values. The model MCB performs the flow rate calculation every 400 ms.
For example, if the moving average process time is set to 2 seconds, the moving
average processing will be carried out 2 sec./400 ms = 5 times.
If pulsation are generated, this function can be used to suppress the flow rate
fluctuations.
The moving average processing can be given by the following formula:
Example) When the moving average processing is set to 2 sec.:
where
q
k
is a value currently measured, and
Q
k
is a previous output value.
Set range: ON / OFF
ON (1.0 to 30.0 s)
Default:
OFF
Electromagnetic
flowmeter
MCB
Response output
Moving average time (s)
Input of step response
Figure 5-3
Output characteristics of moving average processing