When mounting the heater to a wall, ensure hinges are on the
underside so that the lid tilts down in the open position.
Minimum required distances:
a)
19.69in (0.5m) from the side wall.
b)
19.69in (0.5m) from the ceiling.
c)
Installation height above 5.91ft (1.8m).
Installation to Ceiling
Minimum required distances:
d)
9.84in (0.25m) from the side wall
e)
Minimum19.69in (0.5m) from the ceiling
(range: 19.69in (0.5m) -29.53in (0.75m) )
f)
Installation height above 6ft (1.8m)
The heater must be mounted to a wall with the bracket supplied to
allow adequate ventilation.
Never mount or place heater near flammable or combustible
materials.
Generally heaters must be placed at a safe distance (clear space)
of at least 6.56ft/2m from combustible materials and glass walls. If
installed in workshops or garages where inflammable or
combustible paints are used, the heaters must be installed at a
distance of at least 13.12ft/4m from the source of danger.
If the heaters are placed in areas where spray painting of any kind
is taking place, they should not be used during the painting
operations.
Never use the heater in particularly dusty areas.