7. Adjusting the machine based on tube diameter:
Final position:
Clamped tube.
The electrode axis aimed at the centre of the pipe.
H = distance between the tube and the electrode
Electrode positioning with reference to the weld joint.
Note: For accurate adjustment, set several parameters simultaneously and
repeat the operation if necessary.
IMPORTANT
: Arc height adjustment should be carried out with care. In fact, most welded pipes have
a slight ovalisation deformity. Depending on the selected tube, make sure the adjustment is done
properly so that the electrode does come into contact with the weld pool. If in doubt, increase the tube-
electrode distance by a few tenths. The standard adjustment is the wall thickness.
It is easier to make this adjustment more accurately using a spacer between the pipe and the flat end
of the electrode.
See
the
various
possibilities
of
torch
adjustment in the pages
of following ones
Hose fixation
system
Hose support
The electrode
axis is aimed
at the centre of
the tube
Torch arm indexing
Electrode axial
control