![Axpert MKS III User Manual Download Page 34](http://html1.mh-extra.com/html/axpert/mks-iii/mks-iii_user-manual_3041282034.webp)
32
Faults Reference Code
Fault Code
Fault Event
Icon on
01
Fan is locked when inverter is off.
02
Over temperature
03
Battery voltage is too high
04
Battery voltage is too low
05
Output short circuited or over temperature is detected by
internal converter components.
06
Output voltage is too high.
07
Overload time out
08
Bus voltage is too high
09
Bus soft start failed
10
PV over current
11
PV over voltage
12
DCDC over current
51
Over current or surge
52
Bus voltage is too low
53
Inverter soft start failed
55
Over DC voltage in AC output
57
Battery connection is open
58
Current sensor failed
Warning Indicator
Warning
Code
Warning Event
Audible Alarm
Icon flashing
01
Fan is locked when inverter is on.
Beep three times every
second
02
Over temperature
None
03
Battery is over-charged
Beep once every second
04
Low battery
Beep once every second
07
Overload
Beep once every 0.5 second
10
Output power derating
Beep twice every 3 seconds
32
Communication interrupted
None
Eq
Battery equalization
None
bP
Battery is not connected
None