background image

0 2

EN

A S S E M B L Y   (see page 12)

 

S A F E T Y   N O T E S

Gloves should be worn during installation to prevent crushing and cutting injuries.

The product may only be used for bathing, hygienic and body cleaning purposes.

Children as well as adults with physical, mental and/or sensoric impairments must 
not use this product without proper supervision. Persons under the influence of 
alcohol or drugs are prohibited from using this product.

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

The product may not be used as a holding handle. A separate handle must be 
installed.

The hot and cold supplies must be of equal pressures.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and tested as per the applicable 

standards.

⁄  The plumbing codes applicable in the respective countries must be observed.
⁄  The mesh washer must be insert to protect the shower against incoming dirt by 

pipework. Incoming dirt leads to defects or/and can damage parts of the shower; 
such caused faults voids all liability and guarantee claims.

T E C H N I C A L   D A T A
Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Centre distance: 

150±12 mm 

Connections G 1/2: 

cold right - hot left 

Thermal disinfection: 

max. 70°C / 4 min

⁄  Safety against backflow
⁄  The product is exclusively designed for drinking water!

S Y M B O L   D E S C R I P T I O N

Do not use silicone containing acetic acid!

S A F E T Y   F U N C T I O N   (see page 05)

The desired maximum temperature for example max. 42º C can be pre-set 
thanks to the safety function.

A D J U S T M E N T   (see page 05)

After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the output 
differs from the temperature set on the thermostat.
M A I N T E N A N C E   (see page 12)

⁄  The check valves must be checked regularly according to DIN EN 1717 

in accordance with national or regional regulations (at least once a year).

⁄  To guarantee the smooth running of the thermostat, it is necessary from 

time to time to turn the thermostat from total hot to total cold.

D I M E N S I O N S   (see page )

F L O W   D I A G R A M   (see page 07)

 Hand shower

 Bath Spout

S P A R E   P A R T S   (see page 10)

C L E A N I N G   (see page 11)

O P E R A T I O N   (see page 06)

H O T   A N D   C O L D   S U P P L I E S   A R E   R E V E R S E D 
(see page 12)

F A U L T

C A U S E

R E M E D Y

⁄  Insufficient water

⁄  Supply pressure inadequate

⁄  Check water pressure (If a pump has been installed check 

to see if the pump is working).

⁄  Regulator filter dirty

⁄  Clean filter in front of the mixer and on the MTC-thermo car-

tridge

⁄  Shower filter seal dirty
⁄  filter insert shower dirty

⁄  Clean filter seal between shower and hose
⁄  Clean filter insert between shower and hose

⁄  Crossflow, hot water being forced into cold water pipe, or 

vice versa, when mixer is closed

⁄  Backflow preventers dirty or leaking

⁄  Clean backflow preventers, exchange if necessary

⁄  Spout temperature does not correspond with temperature 

set

⁄  Thermostat has not been adjusted

⁄  Adjust thermostat

⁄  Hot water temperature too low

⁄  Increase hot water temperature to 42 ºC to 65 ºC

⁄  Temperature regulation not possible

⁄  thermo cartridge calcified

⁄  Exchange thermo cartridge

⁄  For new installations: basic body incorrectly connected 

(should be: cold right, hot left) or installed with 180º rota-

tion

⁄  Install function block turned through 180º (see page 12)

⁄  Safety stop button not operating

⁄  Spring defective
⁄  Button calcified

⁄  Clean spring and/or button, exchange if necessary

⁄  Valve stiff

⁄  Shut-off unit damaged

⁄  Exchange shut-off unit

⁄  Shower or spout dripping

⁄  Dirt or sedimentation on valve seat.

⁄  Clean or exchange shut-off unit

Summary of Contents for Urquiola 11437009

Page 1: ...I N S T A L L A T I O N E N Instructions for use assembly instructions 02 D E Gebrauchsanleitung Montageanleitung 03 AXOR Urquiola 11437009 11438009 ...

Page 2: ...function A D J U S T M E N T see page 05 After the installation the output temperature of the thermostat must be checked A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat M A I N T E N A N C E see page 12 The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations at lea...

Page 3: ... J U S T I E R U N G siehe Seite 05 Nach erfolgter Montage muss die Auslauftemperatur des Thermostaten überprüft werden Eine Korrektur ist erforderlich wenn die an der Entnahme stelle gemessene Temperatur von der am Thermostaten eingestellten Temperatur abweicht W A R T U N G siehe Seite 12 Rückflussverhinderer müssen gemäß DIN EN 1717 regelmäßig in Übereinstimmung mit nationalen oder regionalen B...

Page 4: ...0 4 2 4 3 1 2 3 4 1 2 SW 8 mm 94246000 6 x M10x35 SW 8 mm 5 6 7 SW 22 mm 2 min SW 22 mm 2 Nm 10452180 1 1 2 10 mm ...

Page 5: ...0 5 2 1 SW 3 mm 1 1 2 2 z B 42 C for example 42 C 3 5 6 SW 3 mm 2 mm 4 1 2 3 SW 3 mm 2 Nm ...

Page 6: ...0 6 1 2 4 0 C cold kalt open öffnen close schließen hot warm 1 2 ...

Page 7: ...2 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 AXOR Urquiola 11437009 11438009 AXOR Urquiola 11437009 AXOR Urquiola 11438009 0 7 ...

Page 8: ...0 8 1 1 2 3 2 3 5 4 94074000 94074000 4 3 2 2 1 1 6 x M10x35 SW 8 mm 6 x M10x35 SW 8 mm ...

Page 9: ...0 9 2 3 180 1 2 1 6 x M10x35 SW 8 mm 4 4 3 2 1 6 x M10x35 SW 8 mm ...

Page 10: ...1 25 m 98193000 32x2 11492000 11491000 95181000 98916000 98162000 44x2 5 98190000 36x2 5 94246000 94074000 94074000 97664000 M5x25 SW 4 mm 98371000 29x3 98127000 11x2 97670000 M 10x35 SW 8 mm M4x14 SW 3 mm 98058000 M4x8 SW 2 mm 98913000 M34x1 5 SW 27 mm 98170000 10x2 AXOR Urquiola 11437009 11438009 ...

Page 11: ...on w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation E N Cleaning recommendation Warranty Contact D E Reinigungsempfehlung Garantie Kontakt 1 min 1 2 4 3 5 2 1 ...

Page 12: ...AXOR Hansgrohe SE Auestraße 5 9 77761 Schiltach Deutschland info axor design com axor design com 02 2020 9 04683 61 ...

Reviews: