S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective coun-
tries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
Centre distance:
150 ±16 mm
Connections R 1⁄2:
cold right - hot left
Safety against backflow
The product is exclusively designed for drinking water!
C L E A N I N G (see page 40)
O P E R A T I O N (see page 39)
S P A R E P A R T S (see page 36)
XXX = Colors
000 = Chrome Plated
820 = Brushed Nickel
930 = Polished Brass
A S S E M B L Y (see page 31)
D I M E N S I O N S (see page 35)
A D J U S T M E N T (see page 33)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
M A I N T E N A N C E (see page 32)
The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N