background image

0 2

A S S E M B L Y   (see page 04)

EN

 

S A F E T Y   N O T E S

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pressures.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and 

tested as per the applicable standards.

⁄  The plumbing codes applicable in the respective 

countries must be observed.

⁄  The drain valve must only be used as intended. It is not 

allowed to attach other objects to the drain valve, for 
example a semi-pedestal.

T E C H N I C A L   D A T A
This mixer series-produced with EcoSmart

®

 (flow limiter)

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

S Y M B O L   D E S C R I P T I O N

Do not use silicone containing acetic acid!

D I M E N S I O N S   (see page 09)

F L O W   D I A G R A M   (see page 09)

S P A R E   P A R T S   (see page 11)

S P E C I A L   A C C E S S O R I E S 
(order as an extra)

extension #31971000 (see page 11)

C L E A N I N G   (see page 10)

O P E R A T I O N   (see page 10)

Summary of Contents for Citterio 39114009

Page 1: ...I N S T A L L A T I O N E N Instructions for use assembly instructions 02 D E Gebrauchsanleitung Montageanleitung 03 AXOR Citterio 39114009...

Page 2: ...be observed The drain valve must only be used as intended It is not allowed to attach other objects to the drain valve for example a semi pedestal T E C H N I C A L D A T A This mixer series produced...

Page 3: ...en sind einzuhalten Das Ablaufventil darf nur zum bestimmungsgem en Gebrauch verwendet werden Das Befestigen von anderen Gegenst nden z B einer Halbs ule an dem Ablaufventil ist nicht zul ssig T E C...

Page 4: ...0 4 3 1 SW 17 mm SW 30 mm 4 5 13623180 2 1 mm 2 Silicone S i l i c o n e 1...

Page 5: ...0 5 SW 27 mm 10 Nm SW 2 mm 2 Nm 8 1 0 7 9 11 6...

Page 6: ...0 6 82 92 92 102 102 112 12 A B C 33 23 14...

Page 7: ...0 7 15 X 30 mm SW 12 mm 13 15 17 1 4 1 6 18...

Page 8: ...0 8 SW 3 mm 3 Nm 10 Nm 1 9 21 2 4 2 3 2 6 2 0 2 2 2 5 SW 22 mm 2 min SW 22 mm 2 Nm 1 2 3...

Page 9: ...5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec AXOR Citterio 39114009 100 220 100 22...

Page 10: ...commendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w...

Page 11: ...1 3 8 l min 96908000 96912000 39092000 92930000 97239000 97695000 96914000 95169000 21 95x1 78 31971000 98383000 34x2 98383000 34x2 97971000 A C B 97228000 98134000 16x2 5 95644000 95645000 97601000 9...

Page 12: ...08 2020 9 05684 61 AXOR Hansgrohe SE Auestra e 5 9 77761 Schiltach Deutschland info axor design com axor design com...

Reviews: