43
AXOR Industries
Service Manual
Nano Mack
®
ver.1 rev.11/'19
2.12 Digital inputs connection
DIGITAL INPUTS
connection
DIGITAL INPUTS
configuration
Notes
:
•
The enable signal should be +
24V
dc
- 7mA
(PLC compatible). The enable range is between
+14 ÷30V
dc
;
they are disabled with a voltage less than
+5V
dc
.
• The
J1-1
terminal (
D.IN1 (ENABLE)
) is pre-setted as the drive’s enable. If
J1-1
is
HIGH
(+24VDC)
the drive is enabled (without active alarms and if start up sequence is respected);
If
J1-1
is
LOW (0V)
, the drive is disabled and the motor is without torque.
ATTENTION:
THE DRIVE'S ENABLE/DISABLE, BY USING THE DIGITAL INPUT, IS NOT CONSIDERED A
SECURITY FUNCTION.
HARDWARE
STATUS
SOFTWARE
STATUS
ENABLED
DISABLED
Under
FUNCTIONS
is possible to assign a function from the list (
see cap. 5.8 Digital I/0 window on
) to the digital input, if required form the function the
VALUE
box will be enabled.
DGT-IN1 (ENABLE)
+24VDC
I/O GND
AGND
CN
Nano Mack
J1
3
12
DGT-IN4
6
DGT-IN3
5
DGT-IN2
4