REPLACEMENT & ADJUSTMENT
Replace the main blade
Disconnect the saw from the power source!
The main blade dimension suitable for
machine is
254x30x3( outer diameter, core diameter, thickness),
305x30x3, 315x30x3mm.
Replace and adjusting the scoring blade
But any time you change blade thickness, the
Disconnect the saw from the power source!
appropriate sized riving knife and scoring blade
must also be changed to match the size of main
blade you install.
Suitable for
machine is 90x20x3( outer diameter, core
diameter, thickness) mm
Tapered Scoring Blade.
To change main blade:
1
.
Move the blade tilt to 0˚ (Blade 90˚ to table) on the
To replace scoring blade:
control panel and raise the blade as far as it will go.
1
.
Move the blade tilt to 0˚ (Blade 90˚ to table) on the
2
.
Move the sliding panel all the way to the right and
control panel and raise the blade as far as it will go.
remove two M6x12 pan head screws to expose the
internal blade guard that covers the blades and
2
.
Move the sliding panel all the way to the left and
riving knife.
remove two M6x12 pan head screws to expose the
internal blade guard that covers the blades and
3
.
Remove the blade guard from the riving knife to
riving knife.
expose the mounting assembly.
3
.
Remove the blade guard from the riving knife to
4
.
Remove the table insert.
expose the mounting assembly.
5
.
Insert the arbor pin into the hole on blade inner
4
.
Remove the table insert.
flange and locks the blade.
5
.
Insert the arbor pin into the hole on blade inner
6
.
Using the arbor wrench, remove the arbor nut that
flange and locks the blade.
secures the main blade (turn clockwise to loosen).
6
.
Using the arbor wrench, remove the arbor nut that
7
.
Remove the arbor flange and the old main blade.
secures the main blade (turn anti-clockwise to
loosen).
8
.
Install the new main blade, replace the arbor flange
and nut, and tighten the arbor nut to secure the
7
.
Remove the arbor flange and the old scoring blade.
main blade.
8
.
Install the new scoring blade, replace the arbor
flange and nut, and tighten the arbor nut to secure
the scoring blade.
If you changed blade diameter sizes during this
procedure, now is the time to adjust the riving knife.
(Just for
)
If the kerf thickness is different from your old blade,
the scoring blade kerf and riving knife thickness
must match the new main blade kerf.
9
.
Make sure the correct size riving knife is installed
and aligned with the blade.
10
.
Move the internal blade guard back into its original
position, next to the blades, and center the sliding
panel.
11
.
Align the scoring blade to the main blade .
13
Fig
25
Fig
26
MJ12
MJ12
Summary of Contents for 951685
Page 1: ...951685 MJ12 1600 Panel Saw Axminster Reference No MJ12 1600 User Manual www axminster co uk...
Page 6: ...GETTING TO KNOW YOUR SLIDING PANEL SAW 5...