Troubleshooting
22
Symptom
Possible Causes
Solutions
Morticer will not start
1. Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit breaker
2. Cord damaged.
Replace the power cord by a qualified
electrician.
Overload kicks out frequently
1. Extension cord too light or too long.
1. Replace with adequate size cord.
2. Chisel and bit in poor condition
(dull or broken).
2. Clean or replace the chisel and bit.
3. Timber is too wet.
3. Dry timber before cutting.
Bit does not come
up to full speed
1. Extension cord too light or too long.
1. Replace with adequate size cord.
2. Low current.
2. Consult a qualified electrician.
3. Motor not wired for correct voltage.
3. Check motor name plate for
correct wiring or consult a qualified
electrician.
Morticer makes
unsatisfactory cuts
1. Dull hollow square chisel and bit.
1. Sharpen or replace the chisel and
bit.
2. Gum or pitch on the chisel and bit.
2. Remove the chisel and bit and clean
using “Axcaliber Blade and Bit
Cleaner Code 951145” .
3. Gum or pitch on the worktable or
fence causing an un-square cut
3. Clean the worktable and fence as
described above.
4. The chisel and bit was not correctly
set.
4. Make sure the entire assembly is
correctly held with proper clearance
of 2mm-5mm.
The work starts to burn
1. Dull chisel and bit.
1. Sharpen or replace the chisel and bit.
2. The bit has worn out or is broken.
2. Replace the worn bit with a new one.
The drill bit is down drilling
1. The bit is worn out or broken.
1. Replace the worn bit with a new
one.
2. The bit is not sharp enough.
2. Sharpen the bit.
3. The drill bit has come loose in
the chuck.
3. Tighten the drill chuck with the key
provided.
The machine vibrates
1. Damaged chisel bit.
1. Replace the damaged bit with a
new one.
2. Stand on uneven floor.
2. Reposition on flat level surface.