AXIS T99A11 Positioning Unit 24 V AC/DC
Specifications
To find the latest version of the product’s datasheet, go to the product page at
and
locate
Support & Documentation
.
Connectors
Network connector
RJ45 Ethernet connector.
SFP connector.
NO
NO
NOTICE
TICE
TICE
The product shall be connected using a shielded network cable (STP) or an optical fiber
cable. All cables connecting the product to the network shall be intended for their
specific use. Make sure that the network devices are installed in accordance with
the manufacturer’s instructions. For information about regulatory requirements, see
Electromagnetic compatibility (EMC) on page 8
.
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection,
event triggering, and alarm notifications. In addition to the 0 V DC reference point and power (DC
output), the I/O connector provides the interface to:
Digital input -
For connecting devices that can toggle between an open and closed circuit, for
example PIR sensors, door/window contacts, and glass break detectors.
Digital output -
For connecting external devices such as relays and LEDs. Connected devices can
be activated by the VAPIX® Application Programming Interface or from the product’s webpage.
6-pin configurable terminal block
Function
Pin
Notes
Specifications
DC ground
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
34
Summary of Contents for T99A11
Page 1: ...AXIS T99A11 Positioning Unit 24 V AC DC Installation Guide ...
Page 2: ......
Page 14: ...14 ...
Page 42: ...42 ...
Page 68: ...68 ...
Page 72: ...72 ...
Page 98: ...98 ...
Page 102: ...102 ...
Page 128: ...128 ...
Page 132: ...132 ...
Page 160: ...160 ...
Page 211: ...211 ...