![Axis Q7436 User Manual Download Page 39](http://html1.mh-extra.com/html/axis/q7436/q7436_user-manual_3038627039.webp)
AXIS Q7436 Video Encoder Blade
Events
-
Live Stream Accessed
– Trigger the rule when any stream is accessed and during edge storage playback.
This can for example be used to send notifications.
-
Tampering
– Trigger the rule when tampering is detected. See
About camera tampering on page 30
•
Hardware
-
Video Signal
– Trigger the rule if video signal is lost.
-
Network
– Trigger the rule if network connection is lost or restored.
-
Temperature
– Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notifications.
•
Input Signal
-
Digital Input Port
– Trigger the rule when an I/O port receives a signal from a connected device. See
-
Manual Trigger
– Trigger the rule using the
Manual Trigger
button in the Live View page. See
. This can for example be used to validate actions during product installation
and configuration.
-
Virtual Inputs
– can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
•
PTZ
-
Error
– Trigger the rule if the PTZ functionality is not working correctly. This can for example be used to
send maintenance notifications.
-
Ready
– Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer
the camera to a specific preset position when the product is started.
•
Storage
-
Disruption
– Trigger the rule if storage problems are detected, for example if the storage device is unavailable,
removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance
notifications.
-
Recording
– Triggers the rule when the Axis product records to the storage device. The recording status trigger
can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can be used only for edge storage recording status.
•
System
-
System Ready
– Trigger the rule when the product has been started and all services are running. This can for
example be used to send a notification when the product restarts.
•
Time
-
Recurrence
– Trigger the rule periodically. See
. This can for example be used to
upload an image every 5 minutes.
-
Use Schedule
– Trigger the rule according to the selected schedule. See
Actions
Available
actions
include:
•
Output Port
– Activate an I/O port to control an external device.
•
Overlay Text
– Display an overlay text. See
How to include overlay text in an action rule on page 22
.
•
PTZ Control
39