background image

Axis P55 & Q60 HD network/IP PTZ cameras with Dotworkz D2 Outdoor Housing -

10 minute installation guide

www.dotworkz.com  

 

866.575.4689

innovative      

remote video solutions

Using the included Axis 

Torx screw driver unscrew 

all 8 bottom Torx screws (4 

“outside” ones for the main 

cover plus 4 for smaller 

cables latch cover).

Attach the Axis P55 or Q60 

series camera collar to the 

Dotworkz universal camera 

mounting plate, making sure 

to line up correctly and tight-

ening lock washers securely.

Connect BROWN wire to 

(-) negative and RED to (+) 

positive on the MVP terminal. 

The BLACK wire is not used 

so we recommend isolating 

it with electrical tape.

Run CAT5 cable through exist-

ing D2 cable gland; Remove 

the plug and install an included 

second cable gland, making 

sure to seal it tight. Note: if 

using conduit be sure sealing 

to avoid water moisture.

After unscrewing, remove 

P55 or Q60 series camera 

cover and open smaller cable 

latch. Set aside the main 

lower camera shroud as it is 

not going to be needed.

You will need to use the 1.5 

and the 0.75 inches stand-

offs on the 4 brass inserts 

on top of the D2 enclosure - 

DO NOT over tighten or cross 

thread the standoffs.

Have a qualified electri-

cian connect an external 

power source to D2 terminal 

power block. See manual for     

more details.

Attach the Dotworkz 5502-491 

patch cable that will provide 

camera power; attach the 

RG45 connector of a CAT5 

Ethernet cable to the camera; 

Feed both cables out their 

respective slots.

Twist-lock camera into collar 

while applying down pressure; 

line up the diamond mark as 

in this picture; Secure the 

camera plate to the standoffs 

using included 832 pan  

head screws.

Make sure to have only one 

cable per gland and tighten 

them really shut to com-

pletely seal D2 enclosure 

from the outside.

Securely close the cable 

latch using the Torx screw  

driver again.

Remove the terminal block 

from Dotworkz 5502-491 

cable: you will only use 

BROWN and RED wires.

Check camera install by care-

fully closing the D2 camera 

hatch and verifying clearance 

between camera and D2 

lens: should be enough space 

between the clear dome and 

the camera to move freely.

Close the enclosure and 

tighten all screws using 

a philips screw driver. 

The D2 can be mounted 

directly to a wall or to a pole           

mount adapter.

Make sure to create a “U” 

shape drip loop with the 

cables to prevent water 

from pooling and possibly     

seeping inside.

Axis Technology,           
Dotworkz Durability 

Dotworkz has created a quick “how-

to” guide on proper installation of 

the Axis 

P5512, P5522, P5532, 

P5534, Q1755, Q6032, Q6034, 

Q6035

 HD cameras with the 

Dotworkz D2 rugged IP66 camera 

enclosures. Guide includes step-by-

step photos, procedures and tips for 

a fast and simple set up.
The Dotworkz housings are the #1 

choice available to protect Axis HD 

cameras. An IP66 rating assures 

that the cameras and all other 

sensitive electronic equipment are 

safe from environmental conditions, 

and secure from malicious vandals.  

Dotworkz enclosures are the durable 

solution for protecting Axis cameras 

from the harshest conditions.  

Prepare the camera

Install Axis collar

Correct poles

IP68 Cable glands

Remove shroud

Mount the standoffs

External power source

Connect cables

Secure camera

Tighten cable glands

Reassemble latch cover

Using Dotworkz cable

Check camera fit

Close the D2

Leave a drip loop

All the parts and tools

Note: 

Please read both Axis and Dot-

workz manuals before beginning. Photo 
of hardware and components needed 
to install Axis 

P55 & Q60

 into the D2 

outdoor enclosure system.

Reviews: