![Axis I8016-LVE User Manual Download Page 21](http://html1.mh-extra.com/html/axis/i8016-lve/i8016-lve_user-manual_3038334021.webp)
AXIS I8016-LVE Network Video Intercom
Specifications
Connectors
Network connector
RJ45 Ethernet connector with Power over Ethernet (PoE).
Audio connector
4-pin terminal block for audio input and output.
Function
Pin
Notes
Line in
1
Line in (mono)
GND
2
Audio ground
Line out
3
Line out (mono)
GND
4
Audio ground
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input -
For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Digital output -
For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the product’s webpage.
Function
Pin
Notes
Specifications
0 V DC (-)
1
0 V DC
12 V DC
2
Max current = 400 mA
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
0 to max 30 V DC
Configurable
(Input or Output)
3-4
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
0 to max 30 V DC
Common
5
Max current/voltage = 700mA at 30
V external sourced
Normally
open/normally
closed
6
For connecting relay devices. The relay pin is galvanically
separated from the rest of the circuitry.
Max current/voltage = 700mA at 30
V external sourced
21