![AXIOMATIC AX130511 User Manual Download Page 135](http://html1.mh-extra.com/html/axiomatic/ax130511/ax130511_user-manual_3037093135.webp)
UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
135 - 141
Subindex
1h
Description
FD1 Clear Threshold
Access
RW
PDO Mapping
No
Value Range
500 to 5041h at subindex 1 [ºC x 10]
Default Value
850 (85.0ºC)
Subindex
2h
Description
FD2 Clear Threshold
Access
RW
PDO Mapping
No
Value Range
5042h at subindex 3 to
5041h at subindex 2 [V x 10]
Default Value
480 (48.0V)
Subindex
3h
Description
FD3 Clear Threshold
Access
RW
PDO Mapping
No
Value Range
5041h at subindex 3 to
5042h at subindex 2 [V x 10]
Default Value
120 (12.0V)
2.4.85. Object 5050h: FD Enable Error Check 3 Faults
This object enables or disables the fault detection error-checking feature for each fault detectable by the 2IN-
2OUT-SIG-CO. The bitmap for this object at sub-index 1 is:
•
Bit 0: Over Temperature Detection
•
Bit 1: Over Voltage Detection
•
Bit 2: Under Voltage Detection
Object Description
Index
5050h
Name
FD Enable Error Checking 3 Faults
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-index
0h
Description
Number of entries
Access
RO
PDO Mapping
No
Value Range
1
Default Value
1
Sub-index
1h
Description
Error Check for FD 1 to FD 3
Access
RW
PDO Mapping
No
Value Range
Bit Value 0 = Error Check Disabled