UM AX032200 Version 1.0 27-46
Figure 7: Screen Capture of Default Digital Output Setpoints
Name
Range
Default
Notes
Output Type
Drop List
Normal Logic
Refer to Table 8
Toggle Frequency
0…60,000
0
Units in [milliseconds]
Control Source
Drop List
Digital Input
Refer to Table 1
Control Number
Depends on Source Selected
Refer to Table 1
Unlatch Source
Drop List
Control Not Used
Refer to Table 1
Unlatch Number
Depends on Source Selected
-
Refer to Table 1
Enable Source
Drop List
Control not Used
Refer to Table 1
Enable Number
Depends on Source Selected
-
Refer to Table 1
Enable Response
Drop List
Enable When ON
Refer to Table 7
Enable Response Delay
Drop List
False
Enable OFF Delay
0…84,600,000
0
Enable ON Delay
0…84,600,000
0
Override Source
Drop List
Control not Used
Refer to Table 1
Override Number
Depends on Source Selected
-
Refer to Table 1
Override Response
Drop List
Enable When ON
Refer to Table 5
Override State
Drop List
False
Refer to Table 6
On State Minimum Current
0.0... 5.0
0.3
Units in [Amps]
On State Maximum Current
0.0... 5.0
2.0
Units in [Amps]
Table 20: Default Digital Output Setpoints