![AXIOMATIC AX030541 User Manual Download Page 61](http://html1.mh-extra.com/html/axiomatic/ax030541/ax030541_user-manual_3037091061.webp)
User Manual UMAX030541. Version V1 61-116
3.3.1 Object 6220h: DO Write State 1 Output Line
This object shall set a single digital output logic state when the corresponding DO is
being controlled by a CANopen® Message (per Table 5 in Section 1.3)
Object Description
Index
6220h
Name
DO Write State 1 Output Line
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
DOx Write State
Access
RW
PDO Mapping
Yes
Value Range
0 (OFF) or 1 (ON)
Default Value
0 (OFF)
3.3.2 Object 6250h: DO Fault Mode 1 Output Line
This object defines how a single digital output shall respond when a fault condition is
detected on any control input, as described in Table 3.
Object Description
Index
6250h
Name
DO Fault Mode 1 Output Line
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4