USER MANUAL

AX12LF

High Output Column Array

KEY FEATURES

• High Power passive portable Line Array element 

• 12 x 3.5” long excursion neodymium transducers with waterproof cones

• Designed for mobile and installed applications  

• Acoustic transmission line back loading design

• Fast, easy-to-use integrated suspension system  

• 90 - 200 Hz low-frequency extension for AX12C and AX6C systems

• Aluminium frame structure  

• Black or white finish  

INTRODUCTION

The AX12LF Line Array is a passive system equipped with twelve 3.5” long-excursion neodymium transducers with 

waterproof cones, designed to provide low-frequency extension for AX12C and AX6C multiple systems.

Wherever a subwoofer is not needed, such as in speech applications or corporate events, the AX12LF provides a one 

octave low frequency extension to the AX12C and AX6C. The same lightweight aluminum frame box and the common 

suspension systems allow perfect integration with AX12C and AX6C elements.

The AX12LF line array module can be combined in different configurations with the AX12C (or AX6C – basically two 

AX6C correspond to one AX12C). Possible configurations range from a simple two-unit column with one AX12C plus one 

AX12LF suspended or installed on the ground, four-unit columns with one AX12LF at the base or one at the base and 

one at the top, and very large suspended systems with four AX12C and two AX12LF at the back (end fire configuration). 

The AX12LF can be powered using QC Series Class D processed amplifiers. Different presets for different combinations 

are available for the built-in CORE DSP, which can be also remotely controlled using PRONET AX software.

Thanks to the elegant mechanical design the AX12C can be easily transported, while the integrated suspension 

system makes its deployment very fast and simple. Each unit comes with two aluminum brackets and four pins that 

allows multiple array elements to be easily combined either together or with AC12C and AX6C elements, or also in 

combination with the complete range of mounting hardware available, including flybar and several brackets and stands.

TECHNICAL SPECIFICATION

SYSTEM

INPUT CONNECTIONS

System’s Acoustic Principle

Line Array Element

Short Transmission

Line Back Loading

Connector Type

Neutrik® Speakon® NL4 x 2

(1+/1- signal IN & LINK ; 2+/2- thru)

POWER HANDLING

Frequency Response (±3dB)

90 Hz - 200 Hz (Processed)

Continuous AES Pink Noise Power 

320 W

Nominal Impedance

8 Ohm

Program Power 

640 W

Minimum Impedance

5.8 Ohm

ENCLOSURE & CONSTRUCTION

Horizontal Coverage Angle

360°

Width

107 mm (4.2")

Sensitivity (2.83V)

99 dB SPL @ 1m*

Height

1166 mm (45.9") - without flying system 

Maximum (peak) SPL 

124 dB SPL @ 1m*

1212 mm (47.7") - with flying system

TRANSDUCERS

Depth

193 mm (7.6")

Type

12 x 3.5" (88mm) Neodymium 

magnet woofers, 1" (25mm) VC

Enclosure Material

Aluminum

Paint

High resistance, water based paint, black or 

white finish

Cone

Waterproof Cone

Flying system

Aluminum Fast Link structure with dedicated pins

Voice Coil Type

Ventilated voice coil

Net Weight

13.2 kg / 29.0 lbs. (without flying system)

15.3 kg / 33.7 lbs. (with flying system)

*measured @4 m and scaled @1 m

rev01_2018-03

Summary of Contents for AX12LF

Page 1: ...es Class D processed amplifiers Different presets for different combinations are available for the built in CORE DSP which can be also remotely controlled using PRONET AX software Thanks to the elegant mechanical design the AX12C can be easily transported while the integrated suspension system makes its deployment very fast and simple Each unit comes with two aluminum brackets and four pins that a...

Page 2: ... for detailed description and other available accessories SPARE PARTS NL4MP Neutrik Speakon panel socket 95MET300023 AX12C AX12LF front speaker net colour black 94SPI10100 Locking Pin for AX6C AX12C AX12LF 95MET300053 AX12LF rear speaker net colour black 98AX12LFW8 3 5 speaker 1 VC 8 ohm 95MET300023WH AX12C AX12LF front speaker net colour white 95MET300053WH AX12LF rear speaker net colour white 11...

Page 3: ...he load capacity of the appropriate processed amplifier When powered from the QC2 4 and QC4 4 suggested amplifiers a maximum of two AX12LF can be connected to each power output TOOLS This is a list of tools that can be useful to set properly a vertical column array system CABLE TESTER It is a good practice to check all cables before each installation because even one faulty cable can compromise he...

Page 4: ...CAREFULLY READ THE FOLLOWING INSTRUCTIONS AND CONDITION OF USE This loudspeaker is designed exclusively for Professional audio applications The product must be installed by qualified personal only Proel strongly recommends that this loudspeaker cabinet be suspended taking into consideration all current National Federal State and Local regulations Please contact the manufacturer for further informa...

Page 5: ...2 x AX12C speakers are allowed to be installed over a KPTFAX12C serving as ground support The optimal splay angles can be simulated using the EASE Focus 3 software IMPORTANT NEVER INSTALL 2 OR MORE AX12C AX12LF AIMING THE SPEAKERS TO EACH OTHER WITH CLOSED ANGLES In other words NEVER use the 4 STACK posi on between two speakers AX12C AX12LF STACKED USING KPTFAX12C FLOOR STAND WARNING DO NOT STACK ...

Page 6: ...peakers and accessories Brackets MUST be installed by qualified personnel in accordance with safe installation practices A maximum of 2 x AX12C AX12LF speakers can be installed using the KPTWAX12C wall bracket The optimal splay angles can be simulated using the EASE Focus 3 software KPTWAX12C MOUNTING OPERATIONS 1 3 4 2 WARNING DO NOT INSTALL MORE THAN TWO AX12C AX12LF UNITS 5 6 KPTWAX12C AIMING O...

Page 7: ...equired little adjustments During the flown set up you can connect the elements of the array to their cables We suggest to discharge the weight of the cables from the flying pinpoint by tying them with a textile fibre rope for this reason a ring is present at the end of the flybar that can be used to fix the cable instead of letting them hang freely in this way the position of the array will be mu...

Page 8: ...nimum angles maximum angles 0 0 0 2 0 2 0 2 AX12C AX12C AX12C AX12C AX12C AX12C AX12LF AX12LF IMPORTANT NEVER INSTALL 2 OR MORE AX12C AX12LF AIMING THE SPEAKERS TO EACH OTHER WITH CLOSED ANGLES In other words NEVER use the 4 STACK posi on between two speakers ...

Page 9: ...n this kind of setup the rear column of AX12LF must be placed as close as possible to the front column of AX12C and a properly calculated DELAY must be applied to the front column For best results use an acous c measurement system SMAART SATlive or similar to measure delays phase and response of the system ...

Page 10: ...he filtering the time alignment and the speaker protection It must be powered using QC2 4 or QC 4 4 processed amplifiers with the proper preset loaded into the internal processor according to the number of columns connected 1x12LF 1x12C this PRESET should be used for one AX12LF coupled with one AX12C 1x12LF 2x12C this PRESET should be used for one AX12LF coupled with two or three AX12C This preset...

Page 11: ...t 5m ESO2500LU10 lenght 10m ESO2500LU15 lenght 15m ESO2500LU20 lenght 20m ESO2500LU25 lenght 25m ESO2500LU05 lenght 0 25m ESO2500LU05 lenght 0 25m ESO2500LU05 lenght 0 25m IN 0dB 3 6 9 0dB 3 6 9 ID TERMINATE PARALLEL BRIDGE ON COM PROT PROT 1 2 SIGN LIMIT SIGN LIMIT OUT NETWORK ...

Page 12: ...roduct receipt SAFETY INSTRUCTIONS To reduce the risk close supervision is necessary when the product is used near children Protect the apparatus from atmospheric agents and keep it away from water rain and high humidity places This product should be site away from heat sources such as radiators lamps and any other device that generate heat This product should be located so that its location or po...