background image

 

 

 

 

 

 

 

 

 

AX-T520 

 

 

 

 

 

 

 

OPERATION MANUAL 

 

Summary of Contents for AX-T520

Page 1: ...AX T520 OPERATION MANUAL...

Page 2: ...2 CONTENTS 1 Safety information 3 2 Description 5 3 Operating instruction 6 4 Specification 9 5 Battery Fuse replacement 12 6 Accessory 13...

Page 3: ...and confirm this meter without delay 1 1 4 Test leads must be in good condition Before using verify that the insulation on test leads is not damaged and or the leads wire is not exposed 1 1 5 Full com...

Page 4: ...e rear case while voltage is being applied A technician who fully understands danger involved should only carry out such actions 1 4 2 Before opening the case of the meter always disconnect test leads...

Page 5: ...00V o DC AC current measurement 5 ranges from 200 A to 10A o Resistance measurement 7 ranges from 200 to 200M o Diode test o Audible continuity test o Battery test 1 5 6 9V o Telephone Line test RJ11...

Page 6: ...ld the reading if you put the button again data hold will not continue 3 1 5 When only the figure 1 is displayed it indicates overrange situation and the higher range has to be selected 3 2 MEASURING...

Page 7: ...ead to the COM jack and the red test lead to the V jack NOTE The polarity of red lead connection is positive 3 4 2 Set the rotary switch at desired range position and connect test leads across the res...

Page 8: ...d it is recommended the cable be tested again for other faults OPEN There is no OPEN indication A typical cable may have 2 3 or 4 pairs OPENS are displayed as an unlit symbol The user will determine i...

Page 9: ...display 4 SPECIFICATIONS Accuracy is specified for a period one year after calibration and at 18 C to 28 C 64 F to 82 F with relative humidity to 80 4 1 GENERAL MAXIMUM VOLTAGE 1000V DC or 700V AC FUS...

Page 10: ...s AC VOLTAGE Range Resolution Accuracy 200mV 0 1mV 1 2 of rdg 3digits 2V 1mV 0 8 of rdg 3 digits 20V 10mV 200V 100mV 700V 1V 1 2 of rdg 5 digits Input Impedance 10M Frequency Range 40Hz to 400Hz for A...

Page 11: ...10mA 3 0 of rdg 5digits Overload Protection F 200mA 250V fuse for 200 A to 200mA ranges Frequency Range 40Hz to 400Hz for AC Response Average Calibrated in rms of sine wave 4 4 RESISTANCE Range Resolu...

Page 12: ...PLACEMENT If the sign appears on the LCD display it indicates that battery should be replaced Remove screws on the back cover and open the case see the right photo Replace the exhausted battery with a...

Page 13: ...13 6 ACCESSORIES Test Leads Electric Ratings 1000V 10A one set Battery 9V NEDA 1604 or 6F22 one piece Operating Manual one piece...