2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved.
13
2.2.
Wall mounting of MK 8-0xN and MK 12-0xN
The MK 8-0xN and MK 12-0xN head ends have mounting holes on the underside with which they can be hung
on the wall using four suitable screws. We recommend mounting the headend on a perforated mounting plate
QMP 4065 or larger.
The following illustration shows the positions of the four fixing screws to be fitted. A drilling template true to
scale is enclosed with the device.
Note:
The unit must be wall mounted with at least 5 cm clearance along the 4 sides.
The head-end unit can be mounted horizontally or vertically on the wall. For horizontal installation, the
connections are at the top; for vertical installation, they are on the right.