axing MK 12-0 N Series Operation Instructions Manual Download Page 148

Operation instructions | MK 8-0x | MK 16-0x | MK 8-2x | MK 8-0xN | MK 12-0xN 

72 

2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved. 

Type 

MK 8-00 

MK 8-06 

MK 16-00 

MK 16-06 

Comments 

* with software extension only 

** encrypted, cloud-based application for configuration, monitoring and remote maintenance 

 

7.1.2.

 

MK 8-00N | MK 8-03N | MK 12-00N | MK 12-03N 

Type 

MK 8-00N 

MK 8-03N 

MK 12-00N 

MK 12-03N 

Inputs 

Number of tuners 

8 × DVB-S/S2/S2X 

8 × DVB-S/S2/S2X 

12 × DVB-S/S2/S2X 

12 × DVB-S/S2/S2X 

Connector 

8 × F-female 

8 × F-female 

12 × F-female 

12 × F-female 

Frequency range 

900 … 2150 MHz @ DVB-S/S2/S2X 

Input level 

43 … 84 dBµV @ DVB-S/S2/S2X 

Max. LNB current 

250 mA per input 

1000 mA per device 

CI slots 

Input modulation 

Type 

QPSK/8-PSK/8-APSK/16-APSK/32-APSK @ DVB-S/S2/S2X 

Compliance 

DVB-S = EN 300 421 

DVB-S2 = EN 302 307-1 v1.4.1 

DVB-S2X = EN 302 307-2 v1.1.1 

Supported input transport 
streams 

MPEG-2 ISO/IEC 13818 | MPEG-4 ISO/IEC 14496 

Error correction 

auto 

Symbol rate 

1.5 … 45 MS/s (< 40 MSymbol/s in 32-APSK) 

Transportstreams 

Modifiable program 
information 

Program name, SID remapping, PID remapping, PID filtering* TSID, ONID 

LCN 

Yes 

NIT handling @ DVB-C 

auto | off | manual* 

Encryption 

DVB-CSA*, DVB-CISSA*, ATIS-IDSA*, AES-ECB*, AES-CBC* 

Output 

Number of channels 

8 × DVB-C/DVB-T 

8 × DVB-C/DVB-T 

12 × DVB-C/DVB-T 

12 × DVB-C/DVB-T 

Frequency range 

109 … 1006 MHz @ DVB-C 

109 … 862 MHz @ DVB-T 

Channels selectable 

S2…K87 @ DVB-C 

S2…K69 @ DVB-T 

Channel bandwidth 

7/8 MHz @ DVB-T 

Possible frequency shift 

–4 … +4 MHz (0,5-MHz-Schritte) 

Connector 

1 × F-female 

Impedance  

75 Ω 

Summary of Contents for MK 12-0 N Series

Page 1: ...CHP Compact High Performance Kopfstellen MK 8 0x MK 16 0x MK 8 2x MK 8 0xN MK 12 0xN DVB Kopfstellen Betriebsanleitung...

Page 2: ...erbindung ber einen Ethernet Switch zu einem Router 16 2 7 2 Verbindung ber Ethernet over Coax zu einem Router 17 2 8 Verbindung mit einem CASimulcrypt Server mit MKS 1 02 17 3 Konfiguration 18 3 1 An...

Page 3: ...chladen der NIT 58 5 8 7 NIT vom DVB C Eingang hinzuf gen optional 58 5 8 8 NIT zur cksetzen 58 5 9 Logs 59 5 9 1 Log Eintr ge 59 5 9 2 berwachte Tuner 59 5 10 Lizensen 60 5 10 1 Lizenzen f r Software...

Page 4: ...ttps download axing com BAs Sicherheitshinweise_9sprachig pdf Benutzen Sie das Ger t ausschlie lich wie in dieser Betriebsanleitung beschrieben und insbesondere nach dem Stand der Technik Wird das Ger...

Page 5: ...e 67 MK 8 00N 8 unabh ngige Tunereing nge Wandelt 8 DVB S S2 S2X in 8 DVB C oder DVB T abh ngig vom konfigurierten Modulationsverfahren siehe 5 2 auf Seite 47 MK 8 03N Wie MK 8 00N jedoch mit 3 CI Ste...

Page 6: ...Einbau MK 8 00 MK 16 00 MKZ 1 01 Frontplatte f r 19 Einbau mit ffnungen f r CI Slots MK 8 06 MK 16 06 MKZ 1 02 Frontplatte f r 19 Einbau MK 8 00N MK 12 00N MKZ 1 03 Frontplatte f r 19 Einbau mit ffnun...

Page 7: ...n ber acht Ausgangsmodulatoren Die MK 12 0xN verf gen ber 12 Ausgangsmodulatoren Die MK 16 0x verf gen ber 16 Ausgangsmodulatoren Alle Ausgangsmodulatoren lassen sich auf einen beliebigen Ausgangskana...

Page 8: ...ff auf die Ger te Die Verbindung ist passwortgesch tzt und verschl sselt Voraussetzungen vor Ort ist lediglich eine Internetverbindung f r die Kopfstelle z B via LAN EoC 3G LTE Router siehe z B 2 6 au...

Page 9: ...chsanschluss 3 Netzanschluss 4 HF Eingangs LEDs Gelb MPEG Datenstrom vorhanden Aus MPEG Datenstrom nicht vorhanden 5 HF Eing nge 1 bis 4 6 HF Eing nge 5 bis 8 7 HF Eing nge 9 bis 12 nur MK 16 0x 8 HF...

Page 10: ...gang konfiguriert Rot F llstand mindestens eines Modulators zu hoch 2 Potentialausgleichsanschluss 3 Netzanschluss 4 HF Eingangs LEDs Gelb MPEG Datenstrom vorhanden Aus MPEG Datenstrom nicht vorhanden...

Page 11: ...rom vorhanden Aus MPEG Datenstrom nicht vorhanden 5 HF Eing nge 1 bis 4 6 HF Eing nge 5 bis 8 7 Messbuchse 30 dB 8 HF Ausgang 9 Control Schnittstelle f r Konfiguration und CAS Server MK 8 26 MK 8 26 v...

Page 12: ...t darf nur in Innenr umen betrieben werden Installieren Sie das Ger t gem den Sicherheitsbestimmungen der Norm EN 60728 11 2 1 Wandmontage MK 8 0x MK 16 0x und MK 8 2x Die Kompakt Kopfstellen sind ab...

Page 13: ...len die Kopfstelle auf einer Lochblech Montageplatte QMP 4065 oder gr er zu montieren Die folgende Abbildung zeigt die Positionen der vier anzubringenden Befestigungsschrauben Eine ma stabsgerechte Bo...

Page 14: ...tageschrauben ein Achten Sie darauf dass alle vier Montageschrauben in den Befestigungsl chern korrekt einrasten 2 3 Montage im 19 Rack Hinweis Bei 19 Zoll Rack Montage muss mindestens einen Freiraum...

Page 15: ...e des beiliegenden Netzkabels an einer Steckdose an 2 6 HF Anschluss Die Eingangspegel f r die DVB Standards m ssen eingehalten werden siehe Kapitel 7 auf Seite 70 2 6 1 Anschluss an DVB S S2 S2X ber...

Page 16: ...gsversorgung abschalten siehe Abschnitt 4 1 2 auf Seite 23 Aktive DVB T Antennen m ssen extern mit DC versorgt werden 2 6 3 HF Ausgang Verbinden Sie den Ausgang RF OUT mit dem vorhandenen Verteilnetz...

Page 17: ...ntsprechend konfigurierter CAS Server muss vorhanden sein Dieser ist weder Teil der Kopfstelle noch wird der CAS Server in diesem Dokument beschrieben F r das die Kopfstelle muss eine g ltige Lizenz i...

Page 18: ...fsschutz wird mittels Passwortabfrage realisiert IP Adresse 192 168 0 145 Subnetzmaske 255 255 255 0 Der Computer und die Kopfstelle m ssen sich im gleichen Subnetz befinden Der Netzanteil der IP Adre...

Page 19: ...chauswahl gilt f r die Dauer der Sitzung Um sich abzumelden klicken Sie auf ABMELDEN bzw auf LOG OUT falls Sie nicht auf Deutsch umgeschaltet haben Hinweise Wird der Browser ohne vorherige Abmeldung g...

Page 20: ...ingangspegel NIVEAU und das C N Verh ltnis angezeigt 3 2 2 Ausgang Auf der rechten Seite werden die F LLST NDE der Modulatoren angezeigt 100 Modulator F llstand entsprechen der maximalen Netto Datenra...

Page 21: ...gen im Design Druckfehler und Irrt mer vorbehalten 21 3 2 3 Alarme Wenn Alarme Warnungen oder Meldungen der Kopfstelle aktiv sind dann werden diese nach dem Einloggen auf der Startseite angezeigt Das...

Page 22: ...t erscheint eine Fehlermeldung Die Eingabefelder LOF Low Band MHz und LOF High Band MHz beziehen sich auf die Oszillator Frequenzen des LNB im Low und High Band Ab Werk sind die Oszillatorfrequenzen 9...

Page 23: ...S 27 354 27 522 47 682 67 842 S 28 362 28 530 48 690 68 850 S 29 370 29 538 49 698 69 858 S 30 378 30 546 50 706 S 31 386 31 554 51 714 S 32 394 32 562 52 722 S 33 402 33 570 53 730 S 34 410 34 578 5...

Page 24: ...UNDENE PROGRAMME die Radio und TV Sender angezeigt 4 1 5 Deaktivieren eines Tuners Wenn ein Tuner nicht ben tigt wird dann kann dieser deaktiviert werden Der Tuner sucht dann nicht mehr nach Sendern I...

Page 25: ...M1 bis M8 M12 M16 Die Schaltfl chen entsprechen den Modulatoren der Kopfstelle Durch Anklicken der jeweiligen Schaltfl chen in den Tabellen k nnen Programme aktiviert oder auch wieder deaktiviert wer...

Page 26: ...sich das Ger t im REMUX MODE In diesem Modus werden die IDs der eingestellten Transponder und Satelliten bernommen und unver ndert an die Modultoren weitergeleitet Die TS ID1 bis TS ID8 TS ID12 oder...

Page 27: ...n Klicken Sie z B in der Tabelle TUNER 1 auf die Modulator Schaltfl chen M1 Das Programm wird dem Modulator 1 zugeordnet Die Modulator Schaltfl che wird farblich hervorgehoben durch erneutes Klicken w...

Page 28: ...en besser genutzt ndern Sie die Netzwerk ID auf einen Wert gr er Null Klicken Sie auf NDERUNGEN SPEICHERN Die Transportstrom IDs TS ID1 bis TS ID8 12 16 werden automatisch von 1 bis 8 12 16 hochgez hl...

Page 29: ...der Spalte Modulator jeweils auf M2 Die Programme werden dem Modulator 2 zugeordnet Aufteilen der Programme eines Transponders Wenn sich zu viele Programme auf einem Transponder befinden Dann k nnen d...

Page 30: ...r k nnen keine nderungen an den Programmen wie z B LCN Programmname etc vorgenommen werden 4 2 4 LCN Logical Channel Numbering Die LCN Funktion erm glicht eine individuelle Programmplatz Zuordnung f r...

Page 31: ...ew nschten Programmnamen ge ndert haben klicken Sie auf NDERUNGEN SPEICHERN Der die eingegebenen Programmnamen werden in der Kopfstelle gespeichert 4 2 6 Service ID bearbeiten Im Crossmultiplex Modus...

Page 32: ...mme dem Modulator M1 zugeordnet 1 Sowohl beim oberen Programm Das Erste als auch beim unteren Programm Eurosport sind die IN PIDs 101 bis 105 identisch Deswegen werden beim unteren Programm die PIDs r...

Page 33: ...NGEN SPEICHERN Die eingegebenen PIDs werden in der Kopfstelle gespeichert 4 2 8 PID Filtering mit MKS 1 01 Die Transportstr me bestehen aus Paketen die durch PIDs Packet IDentifier gekennzeichnet sind...

Page 34: ...mit der PID 18 bertragen z B Israel PID 90 Die Kopfstelle kann in diesem Fall diese PID in die PID 18 ndern Geben Sie f r die Tuner 1 bis 8 12 bzw 16 die PIDs ein mit denen die EIT bertragen wird 4 2...

Page 35: ...Option NIT Aktivieren Sie unter NIT Tabellenversion die Option Fest Geben Sie eine Version zwischen 1 und 31 ein Hinweis Wenn sich die Senderliste tats chlich ndert dann muss der Suchlauf manuell dur...

Page 36: ...n Dieselbe Eingangs PID kann bei Bedarf zu mehreren Ausgangsmodulatoren weitergeleitet werden Der Ausgangs PID Wert kann f r jeden Ausgang separat eingegeben werden Im folgenden Beispiel wird PID 7496...

Page 37: ...ate kann zwischen 1000 und 7500 frei eingestellt werden Der Standardwert ist 6900 Manche Netzte arbeiten auch mit 6875 Wird mit nur 7MHz Bandbreite gearbeitet ist 6111 gebr uchlich Allgemeiner Ausgang...

Page 38: ...ellten Symbolrate und der DVB C Modulation 16QAM 32QAM 64QAM 128QAM oder 256QAM des Modulators ab Wenn die angezeigte Datenrate mehr als 90 betr gt gibt es verschiedene M glichkeiten dies zu ver ndern...

Page 39: ...l bertragen Bei der Modulation QAM 64 wird die h chste Datenrate erreicht QPSK 2 Bit Symbo geringe Datenrate sehr robustes Signal QAM 16 4 Bit Symbol mittlere Datenrate QAM 64 6 Bit Symbol hohe Datenr...

Page 40: ...ariieren Um den st rungsfreien Empfang zu gew hrleisten ist unbedingt eine Reserve einzuhalten Wir empfehlen einen maximalen F llstand von 90 Wird der maximale F llstand berschritten kann es zu Bildst...

Page 41: ...76 10 246 10 556 16 QAM 1 2 9 953 11 059 11 709 12 064 2 3 13 271 14 745 15 612 16 086 3 4 14 929 16 588 17 564 18 096 5 6 16 588 18 431 19 516 20 107 7 8 17 418 19 353 20 491 21 112 64 QAM 1 2 14 929...

Page 42: ...eliebigen Ausgangskanal einstellen Kein Ausgangskanal darf mehrfach vergeben werden DVB T2 Modulation Die Modulation kann auf folgende Verfahren eingestellt werden QPSK 2 Bit Symbol geringe Datenrate...

Page 43: ...ngsmodus zwischen 1k und 32k ext eingestellt werden 32k ext erm glicht das prozentual k rzeste Schutzintervall und die h chste Daten bertragung FEC L nge Es kann ein FEC Frame mit 64k FEC L nge oder e...

Page 44: ...tto Datenrate des Signales oberhalb der maximalen Netto Datenrate des Ausgangskanals kommt es im Modulator zu einem berlauf Dieser berlauf f hrt zu St rungen Der berlauf des Modulators wird durch die...

Page 45: ...n Unter AKTUELLE EINSTELLUNGEN finden Sie folgende Informationen Firmware Version Zeigt die Version der Firmware und den Typ der Ausgangsmodulation an Software Version Zeigt die Version der Oberfl che...

Page 46: ...pdates zum Download indem Sie auf www axing com im Suchfeld den Artikel eingeben Laden Sie die aktuelle Version auf Ihren PC herunter und entpacken Sie diese Update Unter SOFTWARE DATEI kann eine neue...

Page 47: ...ein bertragungsmodus zwischen 1k und 16k ext eingestellt werden Es stehen 8 Ausgangsmodulatoren zur Verf gung Im Modus DVB T2 4x32K kann ein bertragungsmodus zwischen 1k und 32k ext eingestellt werde...

Page 48: ...er t in ein Netzwerk mit DHCP Server einzubinden Statische IP Adresse Verwenden Sie statische IP Adresse um das Ger t mit einer fest vergebenen IP Adresse in ein Netzwerk einzubinden Hier kann die IP...

Page 49: ...in Klicken Sie auf NDERUNGEN SPEICHERN Das Speichern des Passworts wird Ihnen best tigt 5 3 3 Ger tenamen eingeben Unter GER TENAME k nnen Sie einen Namen f r die Kopfstelle eingeben Geben Sie ins Fel...

Page 50: ...ffnen oder Speichern angeboten Hinweis Passwort und IP Adresse werden nicht gespeichert 5 4 3 Initialisierungsdaten laden Unter EINSTELLUNGEN DER INITIALISIERUNG AUS DATEI LADEN k nnen Sie die gespei...

Page 51: ...immer ausgew hlt Sie k nnen nur Kopfstellen mit gleicher Ausgangsmodulation ausw hlen Klicken Sie auf PDF DRUCKEN Ein PDF der Senderliste wird generiert das Sie ffnen oder speichern k nnen 5 5 Reboot...

Page 52: ...ption Aktiviert Aktivieren Sie wenn gew nscht die Option AXING Support zulassen Geben Sie im Feld Standort eine Bezeichnung des Standorts der Kopfstelle ein Diese Bezeichnung erscheint sp ter im SMART...

Page 53: ...ben Im Feld SNMP Version SNMPv1 oder SNMPv2c w hlen SNMPv2c wird empfohlen Der Community Name das SNMP Passwort lautet per Default public bei Bedarf einen anderen Community Name eingeben Traps Traps k...

Page 54: ...f gens eines Ger ts ob die korrekten Zugangsdaten Passwort eingegeben wurden Standardm ig unterst tzt die Kopfstelle das SNMP v1 v2 Public Profi l Community Name public Folgende SNMP Einstellungen m s...

Page 55: ...diglich die wichtigsten Parameter wie Symbolrate und Modulation beinhaltet Mit der kostenpflichtigen Softwareerweiterung MKS 1 00 kann eine Network Information Table NIT aus den Ger ten ausgelesen edi...

Page 56: ...ichtigen Softwareerweiterung MKS 1 00 kann der Typ auf Manual gestellt werden und eine Network Information Table NIT aus den Ger ten ausgelesen editiert und wieder in die Ger te hochgeladen werden Die...

Page 57: ...ergeben werden Die ON ID muss bei allen Kopfstellen gleich sein 5 8 5 NIT editieren Klicken Sie auf das Stift Symbol neben einer Zeile Die Felder k nnen editiert werden Klicken Sie auf das Plus Zeiche...

Page 58: ...ingang den entsprechenden Tuner aus 5 8 8 NIT zur cksetzen Das Zur cksetzen der NIT ist unter bestimmten Umst nden n tig Beispiel Es werden drei Ger te verwendet Im ersten Ger t wird die NIT editiert...

Page 59: ...log wird in den Flashspeicher geschrieben ist also auch nach dem Neustart noch vorhanden W hlen Sie Statuslog Die Eintr ge des Statuslog werden angezeigt W hlen Sie Systemlog Die Eintr ge des Systemlo...

Page 60: ...e z B TeamViewer Die Kopfstelle muss mit einem PC Notebook ber Ethernet verbunden sein Das Notebook ben tigt einen Internetzugang Sie ben tigen eine g ltige Software Lizenz und die aktuelle Version de...

Page 61: ...ten 61 Das Laden der Datei dauert einige Sekunden Im Dialog AKTIVIERTE LIZENZEN wird die neue Lizenz aufgelistet Starten Sie das Ger t neu melden Sie sich nach dem Neustart erneut an und wechseln Sie...

Page 62: ...CAS Einstellungen werden ge ffnet die Einstellungen sind auf Englisch 5 11 1 Globale CAS Einstellungen Enable Simulcrypt Aktivieren oder Deaktivieren von Simulcrypt zur Aktivierung ist eine Lizenz erf...

Page 63: ...hen gibt es keine M glichkeit zu entschl sseln Fallback Fallback Regel f r den Fall dass die Scrambling Policy nicht erf llt ist w hlbare Optionen Revert to clear Stopp der Verschl sselung Teilnehmer...

Page 64: ...des CAS Lieferanten die das Control Word auf sichere Weise enthalten sowie Berechtigungsinformationen Jeder ECM Eintrag entspricht einem generierten ECM Stream Jede SCG erfordert mindestens einen ECM...

Page 65: ...en kann diese Zelle i d R leer gelassen werden Wenn jedoch eine IP Adresse eingegeben wird sind nur Verbindungen ber diese Adresse m glich CAS CA System aus der CAS List Client ID optional Der Wert mi...

Page 66: ...igste Status Wenn alle verschl sselten Dienste Gr n anzeigen dann funktioniert das System ohne Probleme Wenn jedoch irgendein Programm Rot anzeigt werden unter Wartung CAS weitere Informationen angeze...

Page 67: ...1 CI3 gesteckt werden Stecken Sie die CA Module vorsichtig ohne Kraftaufwand und seitenrichtig in den entsprechenden CI Steckplatz 6 2 CI Men In den CI Men s auf der Startseite der Benutzeroberfl che...

Page 68: ...own um zu einem Auswahlpunkt h her oder tiefer zu gelangen Verwenden Sie Ok um in ein entsprechendes Untermen zu gelangen oder um eine Auswahl zu best tigen Verwenden Sie Menu um in die n chsth here E...

Page 69: ...ng Werkseitig ist in der Spalte Entschl sselung die Option no gew hlt Das Programm wird verschl sselt an den Modulator bergeben und es muss am Empfangsger t entschl sselt werden Wenn in den Kopfstelle...

Page 70: ...84 dB V DVB C 39 84 dB V DVB T T2 LNB Spannung 13 17 V 22 kHz on off DiSEqC 1 0 Max LNB Strom 250 mA je Eingang 1000 mA pro Ger t CI Steckpl tze 6 6 Eingangsmodulation Typ QPSK 8PSK 8APSK 16APSK 32APS...

Page 71: ...DVB C 77 98 dB V DVB T Ausgangsmodulation Konformit t DVB T EN 300 744 DVB C EN 300 429 ITU TJ 83 AnnexA C Typ 16QAM 32QAM 64QAM 128QAM 256QAM DVB C QPSK 16QAM 64QAM DVB T MER 40 dB DVB C 36 dB DVB T...

Page 72: ...egel 43 84 dB V DVB S S2 S2X Max LNB Strom 250 mA je Eingang 1000 mA pro Ger t CI Steckpl tze 3 3 Eingangsmodulation Typ QPSK 8 PSK 8 APSK 16 APSK 32 APSK DVB S S2 S2X Konformit t DVB S EN 300 421 DVB...

Page 73: ...mode DVB T 2K mode DVB T 2K mode DVB T FEC 1 2 2 3 3 4 5 6 7 8 DVB T Schutzintervall 1 4 1 8 1 16 1 32 DVB T Symbolrate 1 7 5 MBaud s DVB C Schnittstellen Control CAS 1 RJ 45 Konformit t Control CAS...

Page 74: ...p QPSK 8PSK 8APSK 16APSK 32APSK DVB S S2 S2X QAM16 QAM32 QAM64 QAM128 QAM256 DVB C QPSK QAM16 QAM64 DVB T QPSK QAM16 QAM64 QAM256 DVB T2 Konformit t DVB S EN 300 421 DVB S2 EN 302 307 1V1 4 1 DVB S2X...

Page 75: ...32K 32Kext mode 4 ch only FEC 1 2 3 5 2 3 3 4 4 5 5 6 Schutzintervall 1 128 1 32 1 16 19 256 1 8 19 128 1 4 Schnittstellen Control CAS 1 RJ 45 Konformit t Control CAS IEEE 802 3 100 Base T Unterst tz...

Page 76: ...Betriebsanleitung MK 8 0x MK 16 0x MK 8 2x MK 8 0xN MK 12 0xN 76 2022 07 27 Technische Verbesserungen nderungen im Design Druckfehler und Irrt mer vorbehalten...

Page 77: ...CHP Compact High Performance Headends MK 8 0x MK 16 0x MK 8 2x MK 8 0xN MK 12 0xN DVB headends Operation instructions...

Page 78: ...s connected to the Internet 16 2 7 2 Connection via Ethernet over Coax to a router which is connected to the Internet 17 2 8 Connecting to a CAS server with MKS 1 02 17 3 Configuration 18 3 1 Login an...

Page 79: ...nput optional 58 5 8 8 Reset the NIT 58 5 9 Logs 59 5 9 1 Log entries 59 5 9 2 Tuner monitoring 59 5 10 Licenses 60 5 10 1 Licenses for Software Extensions 60 5 11 CASimulcrypt with MKS 1 02 62 5 11 1...

Page 80: ...https download axing com BAs Sicherheitshinweise_9sprachig pdf Use the device only as described in these operating instructions and in particular in accordance with the state of the art If the device...

Page 81: ...67 MK 8 00N 8 independent tuner inputs Transmodulates 8 DVB S S2 S2X into 8 DVB C or DVB T depending on the configured modulation standard see 5 2 on page 47 MK 8 03N Like MK 8 00N with 3 CI slots see...

Page 82: ...ont panel for 19 usage MK 8 00 MK 16 00 MKZ 1 01 Front panel for 19 usage with cut outs for CI slots MK 8 06 MK 16 06 MKZ 1 02 Front panel for 19 usage MK 8 00N MK 12 00N MKZ 1 03 Front panel for 19 u...

Page 83: ...odulators 1 6 Output modulators 1 6 1 MK 8 0x MK 16 0x MK 8 0xN MK 12 0xN MK 8 0x and MK 8 0xN have eight output modulators MK 12 0xN have 12 output modulators MK 16 0x have 16 output modulators The m...

Page 84: ...s provides worldwide access to the devices The connection is password saved and scrambled The only requirement on site is an internet connection of the device e g via LAN EoC 3G LTE Router see 2 6 on...

Page 85: ...ulator overload 2 Equipotential bonding connection 3 Mains connection 4 HF input LEDs Yellow MPEG data stream present Off MPEG data stream not present 5 RF input 1 4 6 RF input 5 8 7 RF input 9 12 MK...

Page 86: ...utput configured Red at least one modulator level too high overload 2 Equipotential bonding connection 3 Mains connection 4 HF input LEDs Yellow MPEG data stream present Off MPEG data stream not prese...

Page 87: ...3 Mains connection 4 HF input LEDs Yellow MPEG data stream present Off MPEG data stream not present 5 RF input 1 4 6 RF input 5 8 7 Test port 30 dB 8 RF output 9 Control interface for Configuraton and...

Page 88: ...talled and grounded according to the EN 60728 11 standard Install the device in compliance with the safety regulations defined by the EN 60728 11 standard 2 1 Wall mounting of MK 8 0x MK 16 0x and MK...

Page 89: ...end mounting the headend on a perforated mounting plate QMP 4065 or larger The following illustration shows the positions of the four fixing screws to be fitted A drilling template true to scale is en...

Page 90: ...unting screws down to 1 5 mm e g into the mounting plate Hook the head unit into the four mounting screws Make sure that all four mounting screws engage correctly in the mounting holes 2 3 Mounting in...

Page 91: ...2 5 Power supply The headend has a built in power supply unit Connect the headend to a mains socket using the enclosed mains cable 2 6 RF Installation The input levels for the DVB standards must be co...

Page 92: ...ower supply 2 6 3 RF Output Install the device in compliance with the safety regulations defined by the EN 60728 11 standard Connect the output RF OUT of the device to the established distribution net...

Page 93: ...e the Control interface Requirements Access to an appropriately configured CAS server must be available It is not part of the headend nor is it described in this document A valid license must be insta...

Page 94: ...on is implemented by means of the password prompt IP address 192 168 0 145 Subnet mask 255 255 255 0 The computer and the headend must be in the same subnet The network part of the IP address of the c...

Page 95: ...nd English EN The chosen language applies until the end of the session To log out click LOG OUT Notes If the browser is closed while you are still logged in an automatic logout occurs 2 5 minutes late...

Page 96: ...is calculated Also the LEVEL and the C N ratio are shown 3 2 2 Outputs The fill level of all modulators is shown 100 modulator fill level correspond to the maximal net data rate of the output channel...

Page 97: ...changes in design printing and other errors reserved 21 3 2 3 Alerts If alerts warnings or messages of the head end are active then these are displayed on the start page after logging in The example...

Page 98: ...n error message appears The input fields Low LNB LO Freq MHz and High LNB LO Freq MHz correspond to the oscillator frequencies of the LNB in low and high band The default settings of the oscillator fr...

Page 99: ...63 810 S 24 330 24 498 44 658 64 818 S 25 338 25 506 45 666 65 826 S 26 346 26 514 46 674 66 834 S 27 354 27 522 47 682 67 842 S 28 362 28 530 48 690 68 850 S 29 370 29 538 49 698 69 858 S 30 378 30 5...

Page 100: ...transferred bits is calculated 4 1 4 Found programs After a successful station scanning the radio and TV stations are shown in the area FOUND PROGRAMS The table contains information about the Program...

Page 101: ...M8 M12 M16 The buttons correspond to the modulators of the headend By clicking on the respective buttons in the tables programs can be activated or deactivated again You can assign programs to modula...

Page 102: ...auto the device works in the Remux mode In this mode the IDs from the set transponder and from the satellite are used and forwarded to the modulators with virtually no changes The TS ID1 to TS ID8 TS...

Page 103: ...to the associated modulator For example click in table TUNER 1 on M1 The program is assigned to modulator 1 The button of the modulator is highlighted in colour a new click on a modulator allows the a...

Page 104: ...ibution networks can be optimized Change the Network ID to a value greater than zero Click on SAVE CHANGES The IDs of the transport streams TS ID1 to TS ID8 12 16 are automatically incremented by one...

Page 105: ...or Click in the column Modulator on M2 The programs are assigned to modulator 2 Splitting the programs of a transponder If there are to much programmes transmitted in one transponder they can be split...

Page 106: ...input mode Transmodulator no changes can be made to the programs such as LCN program name etc 4 2 4 LCN Logical Channel Numbering The LCN function enables channel allocation for the station scan of th...

Page 107: ...u have changed the desired program name s click SAVE CHANGES The entered program name s are stored in the headend 4 2 6 Edit service ID In cross multiplex mode you can also edit the service ID Not pro...

Page 108: ...utomatically In the example both programs are assigned to modulator M1 1 The IN PIDs 101 to 105 are identical for both the upper program Das Erste and the lower program Eurosport Therefore the PIDs ar...

Page 109: ...E CHANGES The entered PIDs are saved in the headend 4 2 8 PID Filtering with MKS 1 01 The transport streams consist of packets that are identified by PIDs Packet Identifier With the fee based software...

Page 110: ...untries the EIT is not transmitted with PID 18 for example Israel PID 90 In this case the headend can convert the PID into the PID 18 For tuners 1 to 8 12 or 16 enter the PIDs used to transmit the EIT...

Page 111: ...CED OPTIONS A dialog with options will open Open the NIT option Under NIT version select Fixed Enter a version between 1 and 31 Note If the station list really changes the channel search must be done...

Page 112: ...ecessary enter additional non referenced PIDs The same input PID can be added to multiple outputs if needed Output PID value can be set separately for each output In the example below PID 7496 from th...

Page 113: ...modulation With DVB C modulation you can choose between 16QAM 32QAM 64QAM 128QAM and 256QAM 256QAM enables the highest data transmission rate but it also requires the best network quality DVB C symbo...

Page 114: ...the maximal fill level it may cause image disturbances such as mosaic images The LEDs on the front panel will light up in red in this case The data rate of a DVB C channel depends on the selected cha...

Page 115: ...ssion The QAM modulation process allows reaching higher data rates so that more programs can be transmitted on a channel The QAM 64 modulation gives the highest data rate QPSK 2 bit symbol small data...

Page 116: ...and on the transmission quality To ensure an undisturbed reception a reserve must absolutely be observed We recommend you to set the maximal fill level to 90 If the current fill level exceeds the maxi...

Page 117: ...8 8 709 9 676 10 246 10 556 16 QAM 1 2 9 953 11 059 11 709 12 064 2 3 13 271 14 745 15 612 16 086 3 4 14 929 16 588 17 564 18 096 5 6 16 588 18 431 19 516 20 107 7 8 17 418 19 353 20 491 21 112 64 QAM...

Page 118: ...to 8MHz however with following exception low channels S2 S20 are 7MHz only so those remain in 7MHz Output Channel Each of the modulators can be set to any output channel No output channel may be sele...

Page 119: ...rtest guard interval in percent and the highest data transmission DVB T2 4x32K The transmission mode can be set between 1k and 32k ext 32k ext allows the shortest guard interval in percent and the hig...

Page 120: ...use image disturbances e g mosaic images If the net data rate of the signal exceeds the net data rate of the output channel the modulator overflows This overflow leads to disturbances If the modulator...

Page 121: ...ill find the following information Firmware version Displays the firmware version and the output modulation type Software version Displays the version of the interface Serial number of the device Devi...

Page 122: ...for download by entering the article in the search field on www axing com On the product page you will find the current software firmware in the Downloads tab Download the current version of the file...

Page 123: ...In DVB T2 8x16K mode a transmission mode between 1k and 16k ext can be set There are 8 output modulators available In DVB T2 4x32K mode a transmission mode between 1k and 32k ext can be set There are...

Page 124: ...IP address to connect the device to a network with a DHCP server Static IP adress Use a static IP address to connect the device to a network with a fixed IP address The IP address netmask and the gate...

Page 125: ...Click SAVE CHANGES to confirm and save the changes The saving of the password is confirmed 5 3 3 Device name In the section DEVICE NAME you can set a new device name for the headend Enter a name in th...

Page 126: ...config dat file Click on PDF TO PRINT a PDF is generated and offered as Config pdf for opening or saving Note Password and IP adress will not be saved 5 4 3 Upload Initialization Data In the section...

Page 127: ...This device and is always selected You can only select headends with the same output modulation Click on PRINT TO PDF A PDF of the channel list is generated which you can open or save 5 5 Reboot 5 5...

Page 128: ...ection for the headend In the State field select Enabled Activate if required the option AXING support allowed In the field Location enter a name for the location of the headend This name will appear...

Page 129: ...e SNMP Version field select version SNMPv1 or SNMPv2c SNMPv2c is recommended The Community Name the SNMP password is public by default if necessary enter a different community name Traps Traps can als...

Page 130: ...RTG Network Monitor When adding a device check that the credentials password has been used By default the headend supports the SNMP v1 v2 Public profile community name public The following SNMP settin...

Page 131: ...z to 1002 MHz and only the most important parameters such as symbol rate and modulation With the fee software extension MKS 1 00 a Network Information Table NIT be read from the devices The NIT can be...

Page 132: ...ds for reading checking and uploading the NIT are displayed Note Only with the software extension MKS 1 00 can the type be set to Manual and a Network Information Table NIT be read from the devices ed...

Page 133: ...Different TS IDs must always be assigned The ON ID must be the same for all headends 5 8 5 Edit NIT Click the pen symbol next to a line The fields can be edited Click on the plus sign in the column h...

Page 134: ...IT Select the relevant tuner in the field Tuner input 5 8 8 Reset the NIT Resetting the NIT is necessary in certain circumstances Example Three devices are used In the first device the NIT is edited a...

Page 135: ...after rebooting the headend The status log is written to RAM and is empty after rebooting the headend Choose Statuslog The entries of the status log are displayed Choose Systemlog The entries of the s...

Page 136: ...via remote maintenance software e g TeamViewer The headend must be connected to a PC notebook via Ethernet The notebook requires Internet access You need a valid software license and the current versi...

Page 137: ...rs reserved 61 Under UPLOAD A NEW LICENSE select a LICENSE FILE Click on UPLOAD The upload will take a few seconds The new license is listed in the ACTIVATED LICENSES dialog Reboot the device and log...

Page 138: ...ade under CAS Click on CAS SETTINGS Several fields and tables for the CAS settings are displayed 5 11 1 Global Settings Enable Simulcrypt Enable or disable Simulcrypt license needed to activate Networ...

Page 139: ...allback rule in case Scrambling Policy defined above is not fulfilled Option values Revert to clear Stop scrambling Subscribers will receive programs as unscrambled Also non subscribers are able to vi...

Page 140: ...nformation which carries the control word encryption key in a secure manner and private entitlement information Each ECM entry corresponds to one generated ECM stream Each SCG requires at least one EC...

Page 141: ...separated by Client ID and this cell can be left empty But if IP address is entered only connections from this address are allowed CAS CA System from the CAS List Client ID optional The value EMMG us...

Page 142: ...nt status If all scrambled services have green light system is working without problems But if any service has red light Maintenance CAS page gives more details SCG table status Once SCG status is gre...

Page 143: ...03N or MK 12 03 Carefully insert the CA modules to the corresponding CI slot without exerting force 6 2 CI menu The settings for the CA modules can be made in the CI menus on the start page of the use...

Page 144: ...tting information about authorisation The input and navigation field is used for navigation within the CI menu Use Up or Down to reach a higher or lower selection point Use Ok to enter a corresponding...

Page 145: ...e TUNER table By default in the column Decrypt the option no is choosen The program will be transferred to the modulator in encrypted form and must be decrypted in the receiver If CA modules are plugg...

Page 146: ...S2X 49 84 dB V DVB C 39 84 dB V DVB T T2 LNB voltage 13 17 V 22 kHz on off DiSEqC 1 0 Max LNB current 250 mA per input 1000 mA per device CI slots 6 6 Input modulation Type QPSK 8PSK 8APSK 16APSK 32A...

Page 147: ...n Compliance DVB T EN 300 744 DVB C EN 300 429 ITU TJ 83 AnnexA C Type 16QAM 32QAM 64QAM 128QAM 256QAM DVB C QPSK 16QAM 64QAM DVB T MER 40 dB DVB C 36 dB DVB T Bit rate max 50 87 Mbps DVB C 31 668 Mbp...

Page 148: ...per input 1000 mA per device CI slots 3 3 Input modulation Type QPSK 8 PSK 8 APSK 16 APSK 32 APSK DVB S S2 S2X Compliance DVB S EN 300 421 DVB S2 EN 302 307 1 v1 4 1 DVB S2X EN 302 307 2 v1 1 1 Suppor...

Page 149: ...DVB T 2K mode DVB T FEC 1 2 2 3 3 4 5 6 7 8 DVB T Guard interval 1 4 1 8 1 16 1 32 DVB T Symbol rate 1 7 5 MBaud s Interfaces Control CAS 1 RJ 45 Compliance Control CAS IEEE 802 3 100 Base T Supported...

Page 150: ...QPSK 8PSK 8APSK 16APSK 32APSK DVB S S2 S2X QAM16 QAM32 QAM64 QAM128 QAM256 DVB C QPSK QAM16 QAM64 DVB T QPSK QAM16 QAM64 QAM256 DVB T2 Compliance DVB S EN 300 421 DVB S2 EN 302 307 1V1 4 1 DVB S2X EN...

Page 151: ...K 32Kext mode 4 ch only FEC 1 2 3 5 2 3 3 4 4 5 5 6 Guard interval 1 128 1 32 1 16 19 256 1 8 19 128 1 4 Interfaces Control CAS 1 RJ 45 Compliance Control CAS IEEE 802 3 100 Base T Supported configura...

Page 152: ...Operation instructions MK 8 0x MK 16 0x MK 8 2x MK 8 0xN MK 12 0xN 76 2022 07 27 Technical improvements changes in design printing and other errors reserved...

Reviews: