![axing MK 12-0 N Series Operation Instructions Manual Download Page 131](http://html1.mh-extra.com/html/axing/mk-12-0-n-series/mk-12-0-n-series_operation-instructions-manual_3036761131.webp)
2022-07-27 | Technical improvements, changes in design, printing- and other errors reserved.
55
5.8.
NIT (Network Information Table)
The NIT contains information about the signal configuration of a headend. A TV needs this information for a
fast channel search. The LCN (Logical Channel Numbering) is located within the NIT, which virtually allocates
the programs to a place.
The headend provides an auto NIT at the factory, which includes all channels from 114 MHz to 1002 MHz and
only the most important parameters such as symbol rate and modulation.
With the fee software extension MKS 1-00 a Network Information Table (NIT) be read from the devices. The
NIT can be edited and uploaded back to the devices.
Operation with auto NIT supplies all channels from
114 MHz to 1002 MHz.
Operation leads to a conflict because of two NITs
with ON IDs and Network IDs.
Operation does not lead to conflict (NIT, ON ID,
Network ID). But no LCN from the headend without
MKS 1-00 is delivered.
Ideal solution, operation with MKS 1-00 in each
device: One common NIT, ON ID, Network ID and
LCN from both headends.
5.8.1.
Start NIT Configuration