2018-10-05 | Technical improvements, changes in design, printing- and other errors expected.
7
2.2.
Mounting in a 19“ rack
Note:
For 19-inch rack mounting, there must be at least 5 cm clearance in front of and behind the unit.
Remove the wall bracket from the housing of the HKM 40-0x.
Mount the front plate HKZ 1-00 onto the HKM 40-0x (1).
Slide the HKM 40-0x into the 19 "rack.
Fix the HKM 40-0x with four screws (2).
Maintain the EN 60728-11.
2.3.
HDMI installation
The HKM 40-00 has four HDMI inputs. Connect them to four HDMI sources.
2.4.
RF Output
Connect the output of the HKM 40-0x to the existing distribution network. Use shielded coaxial cables with F
connectors. You can find suitable cables and connectors in the current AXING catalog or at www.axing.com.
If you are using more than one HKM 40-0x, the outputs must be connected with suitable combiner.
2.5.
Power supply
The HKM 40-0x have a built-in power supply (100 ... 240 VAC / 50 ... 60 Hz).
Do not connect the device unit until all assembly and installation work has been completed.
Use the supplied power cord.
Connect the power cord to an appropriate wall outlet.