Axema VAKA A66 Manual Download Page 3

Screw terminals

Connector

Function

1-2

AUX relay (NO/NC)

3-4

Supply voltage (12-35 VDC)

8-9

Exit button *

8, 10

Door contact **

The 100Ω resistor (supplied) is only used when the reader is connected to a door controller.

* Closing the open button input means that the lock is unlocked for the corresponding time (plus the

set opening time).

** When using the door contact, the opening relay returns to the locked position, regardless of the

opening time, as soon as the door is opened. A closed door is to be indicated by a closed contact

between the terminals.

Commissioning the A66

1. Connect the power supply to the A66. (The display will not turn on automatically).

2.

Press A and B simultaneously.

3. When the text

Enter Programming Code appears, enter the code 112233.

4. Select language and press

OK. (Default language is Swedish)

5. Set time and date

The A66 is now ready for programming of codes, tags etc.

3 (8)

ManualA66 Stand alone

Summary of Contents for VAKA A66

Page 1: ...Axema Access ControlAB Box 90215 120 23 Stockholm Sweden 46 0 8 722 34 40 info axema se www axema se Reader VAKA A66 Stand alone Manual Updated 08 11 2021...

Page 2: ...3 Commissioning the A66 3 Real time clock 4 Programming 4 Menus 4 Times 4 Codes 4 Tags 5 Day open and exit button 5 Options 6 Reading 7 Radio 7 SOLO Off line 7 Before you contact support 8 Technical d...

Page 3: ...the opening relay returns to the locked position regardless of the opening time as soon as the door is opened A closed door is to be indicated by a closed contact between the terminals Commissioning...

Page 4: ...ma se download A66_programmeringsmall xlsx Remember to replace the programming code with a self selected 6 digit code Menus Times l Time date setting the time and date l Time schedules programming of...

Page 5: ...me schedule when access tags should be eligibel l Schedule PIN tag choice of time schedule when access tags in combination with PIN code must have authorization PIN code is selected the first time the...

Page 6: ...forcement Agency 6 Testing service and installation l RF transmitter Radio keys Activate Disable Each button for RN18 4 is activated separately Button A applies to RN18 FM and RN18 1 l MIFARE Activate...

Page 7: ...eters i e wall materials vehicle bodies and electrical equipment Before mounting the reader permanently testing with radio key RN 18 is recommended Great improvement can be achieved by moving or redir...

Page 8: ...ins open after the specified unlocking time For that function the UDR Plus can be used Technical data Attribute A66 Stand alone SOLO Reading distance at optimum conditions 7 cm with EM 3 cm with MIFAR...

Reviews: