Plunger Micro Switch Installation Manual
Note: consult with your electrical professional for electrical connection. 120VAC
connection might require hard wired.
Awoco Air Curtains
: Cut the connection nut off
the dedicated 2 wires for door switch, extend and
connect the wires to the micro switch’s NC and
COM poles.
Awoco
Air Curtain
Ground
Neutral
Hot
Plunger Micro switch
120V AC
Power Input
NC NO COM
Other brands’ air curtains
: Cut the power cord’s
Hot wire (usually black color) and connects to the
micro switch NC and COM poles.
Other Brands
Air Curtain
Ground
Neutral
Hot
Hot
Plunger Micro switch
120V AC
Power Input
NC NO COM
The air curtain should be installed indoor, follow the below diagrams for the recommended
installation.
Door Type
Installation Diagram
Applicable
Micro Switch
Models
Installation
Difficulty
Rating
Outward swing doors
If the door swings outward, mount the micro
switch on the side of the door frame or the
upper side of door frame.
TZ-6001
TZ-6003
Easy
Inward swing doors
If the door swings inward, please use metal
sheet to create the brackets (not included) to
install the micro switch.
TZ-6001
TZ-6003
Medium
In & out swing doors
If the door swings in and out, please place
the roller plunger micro switch on the upper
side of the door frame with a metal bracket
(not included) mounted on the top of the door.
TZ-6003
Hard
Middle ended sliding doors
If double sliding doors ended in the middle,
please place the plunger micro switch on the
upper side of the door frame with a metal
bracket (not included) mounted on the top of
the door.
TZ-6001
TZ-6002
TZ-6003
Easy