Note: consult with your electrical professional for electrical connection.  120VAC 
connection might require hard wired.

 

 

Awoco Air Curtains

:  Cut the connection nut off 

the dedicated 2 wires for door switch, extend and 
connect the wires to the micro switch’s  NC and 
COM poles.

 

Awoco

Air Curtain

Ground

Neutral

Hot

Plunger Micro switch

120V AC 

Power Input

NC     NO  COM

 

Other brands’ air curtains

: Cut the power cord’s 

Hot wire (usually black color) and connects to the 
micro switch NC and COM poles. 

 

Other Brands

Air Curtain

Ground

Neutral

Hot

Hot

Plunger Micro switch

120V AC 

Power Input

NC     NO  COM

 

 

The air curtain should be installed indoor,  follow the below diagrams  for the recommended 
installation. 

Door Type 

Installation Diagram 

Applicable 

Micro Switch 

Models 

Installation 

Difficulty 

Rating 

Outward swing doors 

 
If the door swings outward, mount the micro 
switch on the side of the door frame or the 
upper side of door frame. 

 

TZ-6001 
TZ-6003 

Easy 

Inward swing doors 

 
If the door swings inward, please use metal 
sheet to create the brackets (not included) to 
install the micro switch. 

 

TZ-6001 
TZ-6003 

Medium 

In & out swing doors 

 
If the door swings in and out, please  place 
the roller plunger micro switch on the upper 
side of the door frame with a metal bracket 
(not included) mounted on the top of the door. 

 

TZ-6003 

Hard 

Middle ended sliding doors 

 

If  double sliding doors ended in the middle, 
please place the plunger micro switch on the 
upper side of the door frame with a metal 
bracket (not included) mounted on the top of 
the door.

 

 

TZ-6001 
TZ-6002 
TZ-6003 

Easy 