SR-2400 Reader Installation Sheet 

Installation Sheet

  (Wiegand Interface)

SR-2400 Low-Frequency Card Reader

 

 

 

 

 

 

These instructions are for AWID’s SR-2400 Reader, using compatible proximity credentials 

Parts List 

(a)  1  Installation Sheet for SR-2400 
(b)  1  Model SR-2400 Reader 
(c)  2  #6-32 × 1” thread-cutting screw, type 23
(d)  3  Screw-hole plug  (1 spare) 

Preparation 

Reader Location

:  Select the reader’s mounting location.  The SR

1-3/4 inch door frame, or to a wall or other surface.  On a metal surface, read range is reduced about 20%.
The SR-2400 may be installed indoors or outdoors.  The diagram for screw and cable holes is on page 2.

DC Power Supply

:  DC power for this reader is usually supplied from the +DC and Ground terminals of the 

Wiegand reader port on the system’s panel.  If this is not possible, use a separate power supply.  Power may be 
shared with other readers if the supply has sufficient current 
volts DC (as low as +5 volts is OK), 750 milliamperes capacity, linear

Cable

 to Controller and Power Supply:  4 to 6 conductors from the reader to the system (2 wires for DC po

2 wires for Wiegand data, and 1 or 2 wires for external LED and Beeper/Alarm, if used).  22
wires.  Overall 100% 

shield for both power and data

  If the DC power supply is separated from the panel’s reader port, the reader’s 

 

connected to 

both

 the DC power supply’s Negative terminal and the panel reader port’s Ground terminal.

  If the separate DC power supply is close to the reader, run two 22

  

and 3 to 5 wires for Wiegand data (including Ground) and for the external control lines, if used.

  

Both

 cables must be overall-shielded and earth

  Conduit:  If cables are pulled through metal conduit, the conduit should be earth

Installation 

1. 

Connector 

– Cut off the 10-pin in-line connector from the end of the reader’s cable.  D

2. 

Wire Connections 

– Connect the reader’s wires to the cable(s) for power and data.

a.  First, connect 

black

 to the panel port’s Ground terminal, and, if separate, to the power supply Negative.

 

b.  Connect 

green

 to the Data-0 terminal

 

c.  Connect the 

gray 

drain wire to the shield of the connecting cable.

 

If power and data are in separate cables, connect all three drains/shields together near the reader.

 

d.  If the LED and/or Beeper/Alarm feature

 

e.  At the end of the cable(s) near the panel (and near the power supply, if separate), connect the 
 

verified earth-ground. 

 

f.  Last, connect 

red

 to the DC Positive terminal.

Version 2.1 / Doc# 041405 

(Wiegand Interface)        

Frequency Card Reader 

 

 

 

 

 

 

2400 Reader, using compatible proximity credentials 

 

 

cutting screw, type 23 

:  Select the reader’s mounting location.  The SR-2400 Reader may be screwed to a 

3/4 inch door frame, or to a wall or other surface.  On a metal surface, read range is reduced about 20%.

2400 may be installed indoors or outdoors.  The diagram for screw and cable holes is on page 2.

wer for this reader is usually supplied from the +DC and Ground terminals of the 

Wiegand reader port on the system’s panel.  If this is not possible, use a separate power supply.  Power may be 
shared with other readers if the supply has sufficient current capacity.  The power supply should be close to +12 
volts DC (as low as +5 volts is OK), 750 milliamperes capacity, linear-rated, regulated DC output. 

to Controller and Power Supply:  4 to 6 conductors from the reader to the system (2 wires for DC po

2 wires for Wiegand data, and 1 or 2 wires for external LED and Beeper/Alarm, if used).  22

shield for both power and data

.  500 feet maximum length. 

If the DC power supply is separated from the panel’s reader port, the reader’s 

black

 wire 

the DC power supply’s Negative terminal and the panel reader port’s Ground terminal.

If the separate DC power supply is close to the reader, run two 22-gauge cables – 2 wires for DC power, 
and 3 to 5 wires for Wiegand data (including Ground) and for the external control lines, if used.

shielded and earth-grounded (at the end far from the reader).

Conduit:  If cables are pulled through metal conduit, the conduit should be earth-grounded (like the cables).

line connector from the end of the reader’s cable.  D

Connect the reader’s wires to the cable(s) for power and data. 

to the panel port’s Ground terminal, and, if separate, to the power supply Negative.

0 terminal.  Connect 

white

 to the Data-1 terminal. 

drain wire to the shield of the connecting cable. 

If power and data are in separate cables, connect all three drains/shields together near the reader.

features are used, connect the 

brown

 and/or 

yellow

At the end of the cable(s) near the panel (and near the power supply, if separate), connect the 

to the DC Positive terminal. 

Page 1 of 2 

 

 

 

 

2400 Reader, using compatible proximity credentials from AWID. 

may be screwed to a  

3/4 inch door frame, or to a wall or other surface.  On a metal surface, read range is reduced about 20%. 

2400 may be installed indoors or outdoors.  The diagram for screw and cable holes is on page 2. 

wer for this reader is usually supplied from the +DC and Ground terminals of the 

Wiegand reader port on the system’s panel.  If this is not possible, use a separate power supply.  Power may be 

capacity.  The power supply should be close to +12 

rated, regulated DC output.  

to Controller and Power Supply:  4 to 6 conductors from the reader to the system (2 wires for DC power,  

2 wires for Wiegand data, and 1 or 2 wires for external LED and Beeper/Alarm, if used).  22-gauge stranded 

wire 

must

 be 

the DC power supply’s Negative terminal and the panel reader port’s Ground terminal. 

2 wires for DC power,  

and 3 to 5 wires for Wiegand data (including Ground) and for the external control lines, if used. 

ounded (at the end far from the reader). 

grounded (like the cables). 

line connector from the end of the reader’s cable.  Discard the connector. 

to the panel port’s Ground terminal, and, if separate, to the power supply Negative. 

If power and data are in separate cables, connect all three drains/shields together near the reader. 

yellow

 wires. 

At the end of the cable(s) near the panel (and near the power supply, if separate), connect the 

shield

 to a 

 (continued) 