ATEX Retractor System TANKO-RT/-RTS
74/121
Translation - Operating/installation instructions 2020/01
6 Start-up
6.2
Function Check/Trial Run
All the screw connections on the device are firmly tightened in the factory. Nevertheless, a trial run
should be carried out to check that the device functions safely and reliably, and that it is tight once
installed.
Only operate the device in perfect condition.
The container to be cleaned must be emptied and depressurized.
WARNING
Persons in the container. A person could be hit by a jet from the cleaning head!
There is a risk of death or severe physical injury.
Do NOT start the cleaning process while there are persons in the container.
Function check
1.
Close all of the openings on the container (e.g. inspection openings).
2.
Switch off all moving parts in the container (e.g. agitators) and secure them to prevent them from
being inadvertently switched back on or set in motion.
3.
Check to ensure that there is a safe distance around the container and to the surrounding
components.
4.
Switch on the device (see
Section 6.3 Switch-On
5.
Check the interfaces on the device for impermeability.
6.
Make sure that there are no unusual vibrations.
7.
Check the device to make sure that it running smoothly.
8.
Switch off the device (see
Section 7.3