8 Faults
Fault
Cause
Remedy
Effectiveness of cleaning is
not sufficient.
Connection pressure too low.
Check connection pressure,
adjust it.
Connection pressure is too high. Check connection pressure,
adjust it.
Spray slits blocked.
Clean the spray slits.
Spray head does not rotate.
Bearing worn.
Replace the spray head.
Pneumatic cylinder does not
retract.
Locking cylinder does not extend
because:
–
Air supply is interrupted
–
Limit switch or cable on locking
cylinder is defective
–
Locking bolt stuck
–
Check air inlet hose for kinks
and for correct fitting at lock.
–
Replace limit switch or cable.
–
Check locking bolts for dirt or
damage. Replace locking
cylinder, if necessary.
Resistance thermometer
(item 5.03) indicates
a temperature of
66 °C
Temperatures in the environment
or processes are too high:
-
inside the container,
outside the container
-
Temperature of the cleaning
medium
-
Resistance thermometer
(item 5.03) defective
Determine the cause of the
exceeded temperature
immediately and switch off!
-
Replace all limit switches
-
Replace all throttle check
valves.
-
Check resistance
thermometer (item 5.03)
according to manufacturer's
instructions and replace, if
necessary.
Table 8.2-1: Operational Disruptions – Cause and Remedy
If the specified measures are NOT successful, please contact AWH.
If the device is sent back (e.g. repair/service/return), it is necessary for a hazardous substances
declaration to be enclosed with the device in compliance with the German Ordinance on
Hazardous Substances (GefStoffV).
Request the form for the hazardous substance declaration from AWH.