Jet Cleaner TANKO-JM
82/90
Translation of the original Operating / Installation Instructions 2016/12
8 Faults
8.2
Faults and Remedial Action
Fault
Cause
Remedy
Cleaning head and/or
nozzle carrier not rotating
or rotating unevenly.
–
There is no media pressure on the
device.
–
Open the shut-off valve for the
medium.
–
Pressure of the cleaning agent too
low.
–
Increase the pressure (adhere to
the max. permitted pressure).
–
Pressure of the cleaning agent too
high.
–
Reduce the pressure.
–
Excessive friction due to wear on
the bushings and/or bearings.
–
Check the bushings and/or
bearings for wear, clean or replace
them.
–
Actuator unit in the device
damaged or contaminated with
deposits or foreign objects. The
teeth of the spur gears jam.
–
Clean the inside of the device and
remove any foreign objects.
Replace the spur gears.
–
The cleaning head collides with
installed components.
–
Eliminate the interfering contours.
–
Nozzles are blocked mechanically
by interfering contours.
–
Check the position in the
container.
–
Nozzle jet too close to surrounding
components. Due to high media
pressure (recoil).
–
Increase the distance to
surrounding components.
–
Filter or nozzles blocked.
–
Clean the filter or nozzles.
Effectiveness of cleaning
is inadequate.
–
Nozzles soiled or blocked.
–
Clean or replace the nozzles.
–
Pressure of the cleaning agent too
low.
–
Increase the pressure (adhere to
the max. permitted pressure).
–
Volume flow rate too low.
–
Increase the volume flow rate
–
Filter blocked.
–
Clean or replace the filter.
Jet pattern not ideal.
–
No jet concentrators in the
nozzles.
–
Retrofit jet concentrators.
–
Nozzles soiled.
–
Clean the nozzles.
–
Nozzles damaged.
–
Replace the nozzles
Process or media
connection leaking.
–
Seal defective.
–
Replace the seal.
–
Connections have come loose.
–
Check the tightening torque
values of the screw connections.
Volume flow rate too high.
–
Increased leakage due to heavily
worn bushings or bearings.
–
Replace the bushings or bearings.
Table 8.2-1: Operating faults
–
cause and remedy
If the specified measures are NOT successful, please contact AWH.
In the event of return shipment (e.g. repair / servicing / return), a hazardous substance
declaration must be enclosed with the device in accordance with the Hazardous Substance
Directive (GefStoffV).
Request the form for the hazardous substance declaration from AWH.