![Avonic AV-CM44-VCUC-B User Manual Download Page 10](http://html1.mh-extra.com/html/avonic/av-cm44-vcuc-b/av-cm44-vcuc-b_user-manual_3033792010.webp)
10
Back to top
COM port settings
In default working mode, an Avonic camera is able to connect to a VISCA controller with RS-232 or RS-485
serial interface.
The camera can be controlled via RS-232, the parameters of RS-232C are as follows:
•
Baud rate: 2400/4800/9600/115200
•
Start bit: 1 bit.
•
Data bit: 8 bits.
•
Stop bit: 1 bit.
•
Parity bit: none.
The camera can be controlled via RS-485, Half-duplex mode. The parameters are:
•
Baud rate: 2400/4800/9600
•
Start bit: 1 bit.
•
Data bit: 8 bits.
•
Stop bit: 1 bit.
•
Parity bit: none.
Serial Communication Control