File Format and Command Syntax
Configuration files must conform to the following conventions:
•
Each command must begin on a new line.
•
Command words are not case sensitive.
•
Parameters are separated by one or more spaces.
•
Parameters with values that enable or disable connection methods or features use a space
between the keyword and the value. For example:
port 2 tcpserver enable monitordcd enable ipviadhcp disable
•
When enabling/disabling a connection method, the Enable or Disable keyword must be the
first parameter specified after the connection method name. Additional required or optional
parameters may appear in any order following the Enable or Disable keyword.
For example, both of the following commands would result in the same connection method
configuration for port 1.
port 1 telserver enable localipport=2000 timeout=400
buffering=10000
port 1 telserver enable buffering=10000 localippoprt=2000
timeout=400
•
Parameters that include an equal sign and a value (for example Parity=Even) may not contain
any embedded spaces.
•
If you wish to enable a connection method that is mutually exclusive of other connection meth-
ods, and one or more of those methods was enabled previously (either earlier in this or another
configuration file, or through another tool such as the web interface or configuration utility),
you should expressly disable the other connection method in the configuration file before
enabling the mutually exclusive method.
For example, if you wish to enable the modem emulation connection method on a port that
currently has the TCP client connection method enabled, you must first disable the TCP
client method:
port 1 tcpclient disable
port 1 modem enable . . .
•
In commands that require a port number, you may specify
All
instead of a port number if you
wish the command to be applied to all serial ports on the hub.
•
If an optional parameter is not specified in a command, its value remains as is.
The command syntax in this manual uses the following conventions:
•
Variables are shown in italic type surrounding by angle brackets (< >).
•
Choices are separated by a vertical bar (|).
•