92
AVWorks Installer/User Guide
6. To change the Telnet port number, enter a value in the range 3000-65000 in the Telnet Port
Number field.
7. To change the baud rate, choose a value from the pull-down menu in the Baud Rate field.
8. To change the number of data bits, choose a value from the pull-down menu in the Data Bits field.
9. To change the parity, choose a value from the pull-down menu in the Parity field.
10. To change the number of stop bits, choose a value from the pull-down menu in the Stop Bits field.
11. To change the flow control method, choose a value from the pull-down menu in the Flow
Control field. This value cannot share the same signal as the Power On Signal value.
12. To change the toggle signal, choose a value from the pull-down menu in the Toggle Signal field.
13. To change the power on signal, choose a value from the pull-down menu in the Power On
Signal field. This value cannot share the same signal as the Flow Control value.
14. Click
OK
to save the changes locally and exit the dialog box. If any field is invalid, an error
message will appear and the focus will be set to the field in error.
-or-
Click
Cancel
to exit the dialog box without saving changes locally.
15. Click
Apply
to save any changes to the CCM appliance without exiting the AMP.
-or-
Click
OK
to save any changes to the CCM appliance and exit the AMP.
-or-
Click
Cancel
to exit the AMP without saving any changes.
Configuring Port Alert Strings
The Ports - Alerts subcategory lists the defined alert strings for a specified port. You may create,
modify or delete alert strings for each port (except the dedicated CLI port in CCMx50 appliances).
Each port may have up to ten alert strings.
To create, modify or delete port alert strings:
1. Click the
Settings
tab in the CCM AMP.
2. Select the
Ports - Alerts
subcategory.
3. Select a port/device from the Server pull-down menu. The Alert Strings list will contain the
alert strings that have already been defined for that device. If fewer than ten alert strings have
been defined, the list will also contain a
<new>
entry.
4. To create an alert string:
a.
Select
<new>
in the Alert Strings list.
b. In the text box under the list, enter 3-32 characters.
c.
When complete, click the
Check Mark
button.
Summary of Contents for AV Works
Page 4: ......
Page 10: ...viii AVWorks Installer User Guide...
Page 12: ...x AVWorks Installer User Guide...
Page 18: ...6 AVWorks Installer User Guide...
Page 48: ...36 AVWorks Installer User Guide...
Page 92: ...80 AVWorks Installer User Guide...
Page 134: ...122 AVWorks Installer User Guide...
Page 142: ...130 AVWorks Installer User Guide...