MZP RS232 Progammers Manual Device Messages (Class 0)
MZP RS232 Progammers Manual Device Messages (Class 0)
40
Message Details
Class 0: Matrix Mixer Messages
Class 0 messages deal with generic Matrix Mixer information, i.e. information about the
Matrix
mixer itself
, rather than the audio matrix.
00h
Description:
This message is sent by the Matrix Mixer as a reply to an Are You There
message. It is also sent when the Matrix Mixer is powered up or reset.
I Am Here
Source:
Matrix Mixer
Parameters:
none
Reply:
none
Notes:
the checksum is escaped and transmitted in two bytes (F0h and 03h).
Message ID:
1
Are You There
Description:
This message is used as a simple way to verify communication with a
Matrix Mixer. Please refer to
Communication Recommendations
section
11.8.
Message ID:
0
Source:
external
Parameters:
none
Reply:
I Am Here
Notes:
In the following example, the calculated checksum is 255. Since 255 is
greater than the RS232_ESCAPE value of 240, the checksum is escaped and
transmitted in two bytes (F0h and 0Ch).
F0h 0Ch
00h 02h
00h
0
Example
Example
00h 02h
00h
01h
F0h, 0Dh