background image

 

 

 

 

 

Flatbed Imaging Scanner

 

 

User’s Manual 

 

 

 

 

 

 

 

 

 

 

 

Regulatory model: BF-0606H 

 

 

 

 

Avision Inc. 

Summary of Contents for BF-0606H

Page 1: ...Flatbed Imaging Scanner User s Manual Regulatory model BF 0606H Avision Inc ...

Page 2: ...orm or by any means electronic mechanical magnetic optical chemical manual or otherwise without the prior written permission of Avision Inc Material scanned by this product may be protected by governmental laws and other regulations such as copyright laws the customer is solely responsible for complying with all such laws and regulations Warranty The information contained in this document is subje...

Page 3: ...d used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Page 4: ... facilities for recovery and recycling in an effort to protect human health and the environment Fore more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product As an ENERGY STAR Partner Avision Inc has determined that this product meets the ENERGY STAR guide...

Page 5: ...System Requirements IBM compatible PC 586 Pentium or higher Microsoft Windows 98SE Me 2000 XP USB port 2 0 compatible with USB 1 1 At least 100 MB of free hard disk space At least 128 MB of system memory A CD ROM drive ...

Page 6: ... 3 2 Verifying Your Scanner Installation 3 2 3 3 A Glance of the Scanner Properties Dialog Box 3 6 4 Using the Scanner Properties Dialog Box 4 1 4 1 Buttons on the Scanner Properties Dialog Box 4 2 4 2 The Image Tab 4 4 4 3 The Compression Tab 4 17 4 4 The Color Dropout Tab 4 19 4 5 The Paper Tab 4 22 4 6 The Options Tab 4 33 4 7 The Setting Tab 4 38 4 8 The Information Tab 4 41 5 ISIS Interface o...

Page 7: ...g Button Manager 6 2 6 2 Checking the Button Configurations Before Scanning 6 2 6 3 Scanning From One Touch of the Buttons 6 4 7 CARE AND MAINTENANCE 7 1 8 TROUBLESHOOTING 8 1 8 1 Frequently asked Questions 8 1 9 Technical Service 9 1 10 Specifications 10 1 ...

Page 8: ...ductivity Before you install and operate the new scanner please take a few minutes to read through this manual It provides proper instructions for you to unpack install operate and maintain the scanner The following figure indicates the package contents Please check all the items against your checklist If you do not receive all the items please contact your authorized local dealer immediately ...

Page 9: ...24V by Sino American HEG42 240200 7L by Hitron included in the machine Using other AC adapters may damage the machine and void the warranty 2 Please unpack the packing carefully and check the contents against the checklist If any items are missing or damaged please contact your dealer immediately 2 3 1 ...

Page 10: ...cessive heat may cause damage to the unit Do not install the scanner in a humid or dusty place Be sure to use the proper AC power source Place the scanner securely on an even flat surface Tilted or uneven surfaces may cause mechanical or paper feeding problems Retain the scanner box and packing materials for shipping purposes ...

Page 11: ...2 2 2 1 Removing the shipping lock Unlock the scanner by moving the lock switch beneath it to the Unlock position Refer to the Lock Unlock figure on the right side Lock Unlock ...

Page 12: ...ling on some PC s 2 To ensure your computer can identify the USB scanner please install scanner driver first before connecting the scanner to your computer 2 2 1 Connecting to Power Plug the small end of the power adaptor into the power jack of your scanner Insert the other end to an appropriate power outlet Power Cable ...

Page 13: ...olled by a toggle switch on the side of the scanner To turn on the scanner press the switch toward 1 2 2 3 Installing the Scanner Driver 1 Place the supplied CD ROM onto your CD ROM drive 2 The software installation graphic appears If not run setup exe ...

Page 14: ... 2 2 4 Connecting to Computer 1 Connect the square end of the USB cable to the USB port of your scanner Connect the rectangle end to the USB port of your computer 2 The computer should detect a new USB device and prompt a New Hardware Found message Windows 9X Windows ME USB cable ...

Page 15: ...the XP certification screen appears click Continue Anyway to complete the installation 4 When the Finish dialog is prompted click the Finish button 5 Click View Manual to view or print the detailed user manual for the scanner and bundled applications respectively Note To uninstall the scanner driver in Windows XP or Windows 2000 be sure to keep your scanner connecting to your computer ...

Page 16: ...User s Manual 3 1 3 Completing Your First Scan 3 1 Loading Your Paper Align the document to the reference mark as indicated Reference mark ...

Page 17: ...lowing procedure describes how to verify your scanner installation If the installation is not correct please review the preceding section to check if the cable connection and scanner driver have been successfully installed Before you begin be sure the scanner is on 1 Select Start Programs Avision AVxxx Scanner Avision Capture Tool The Select Scanner Model dialog box will be displayed 2 Select your...

Page 18: ...C My Scan Image Note If you do not wish to save the scanned image deselect the Save button since default is Save Enable In this case the thumbnail view will be disabled And therefore after viewing all the scanned images only the last one will remain on the screen 5 Click the Setup button or choose Setup from the File menu to prompt the Scanner Properties dialog box Setup Actual Size Fit Page Scan ...

Page 19: ... Scanner Properties dialog box please see the subsequent chapter Using the Scanner Properties Dialog Box 8 Place your document face down on the document glass or face up in the auto document feeder 9 In the Scan Validation dialog box click the Scan button or choose Scan from the File menu 10 The document will be scanned and displayed in the Scan Validation screen After the scanned images have been...

Page 20: ...n view the scanned image in Fit Page or Actual Size 100 button from the Viewing toolbars at the right side 12 Click the Close box or Quit from the File menu to exit the Scan Validation Tool Fit Page View Status Bar Thumbnail View ...

Page 21: ...of scanner 3 Brightness Adjust the brightness level from 100 to 100 4 Contrast Adjust the contrast level from 100 to 100 5 Resolution Determine the quality of the scanned image The industry standard is 200 dpi 6 Invert Reverse the color of your scanned image 7 Scan Source Choice Auto Document Feeder Flatbed Flatbed Book Automatic varies due to different scanner model 8 Defaults Reset all values on...

Page 22: ... Scanner Properties Dialog Box The Scanner Properties dialog box allows you to configure the scanner s settings It consists of several tabbed windows each of which will be described in this chapter The Scanner Properties dialog box ...

Page 23: ...alog box Buttons Description Defaults Click the Defaults button the factory default settings will be shown on each tab Scan After all the scan settings are satisfactory click the Scan button to start scanning your document Close Click the Close button to leave the Scanner Properties dialog box ...

Page 24: ...None Brightness None Contrast None Compression None Color Dropout None Paper Cropping Automatic Deskew Yes Orientation Portrait OverScan 0 00 Multifeed Detection None Unit Inch Options Rotation Degrees None Blank Page Removal None Edge Fill White 0 mm Image Control Option None Setting Enable Energy Saver Enable 15 minutes after last scan action Show Scanning Progress Yes Show Warning Message Yes S...

Page 25: ...xcept for the resolution you can set individual scan settings for the front side and the rear side For example all settings in the Image tab Compression tab Color Dropout tab can be set individually for the front and the rear side However the settings in the Paper tab the Option tab and the Setting tab have to be set the same for the front and rear side The Image tab dialog box ...

Page 26: ...ment side option If you wish to scan both the front side and the rear side of your color document you can check both Front Color and Rear Color at the same time Note the options vary based on type of scanner Example 1 Scanning a two sided color document both sides in color Side Image Selection Front Rear ...

Page 27: ... other in color Side Image Selection Front Rear Image Type Description Color Choose Color if you wish to scan a color image for your original in color Gray Choose Gray image if your original contains actual shades of gray B W Choose B W if your original contains only text pencil or ink sketch B W Gray Color ...

Page 28: ...cument containing faint text shaded background or color background with a single setting If Dynamic Threshold is selected Threshold Brightness and Contrast are not available Fixed Processing Used for black and white and other high contrast documents A single level is set to determine the black and white transition The threshold is programmable over the entire density range Fixed Processing sets Co...

Page 29: ...n be used to subdue backgrounds and subtle unneeded information A high threshold value produces a darker image and can be used to help pick up faint images Adjust the threshold setting by dragging the Threshold sliding bar to the left or right to achieve the desired threshold setting 200 dpi Threshold 80 Brightness 0 200 dpi Threshold 170 Brightness 0 ...

Page 30: ... the brightness The range is from 100 to 100 Contrast Adjusts the range between the darkest and the lightest shades in the image The higher the contrast the bigger the different grayscale Drag the slider to the right or left to increase or decrease the contrast The range is from 100 to 100 Brightness 50 Brightness 0 Normal Brightness 50 Contrast 50 Contrast 0 Normal Contrast 50 ...

Page 31: ...at 300 dpi at True Color mode consumes approximately 25 MB of disk space A higher resolution usually means over 600 dpi is only recommended when you need to scan a small area at True Color mode Choose a resolution value from the drop down list The default value is 200 dpi Available resolutions are 75 100 150 200 300 400 and 600 Or you may choose your desired value by clicking the box in the right ...

Page 32: ... and the colors in the image The default setting is Black on a White background Reverse mode is White on a Black background For color images each pixel will be changed into its complementary color at the command of Invert Black on White White on Black ...

Page 33: ... document in both the auto document feeder ADF and the flatbed then the scan source will be automatically set to ADF If Automatic is selected and there is document only in flatbed then the scan source will be set to flatbed Note the options vary based on type of scanner 4 2 3 Scanning color images The following options are available for scanning color images y Brightness y Contrast y Resolution y ...

Page 34: ...4 2 5 Scanning B W images The following options are available for scanning B W images y Binarization Dynamic Threshold y Resolution y Invert Or y Binarization Fix Processing y Threshold y Brightness y Resolution y Invert ...

Page 35: ...deleting them To add a new profile 1 Customize your settings For example change your resolution image type cropping method scan size or other scan settings 2 Click the Image tab and then choose Profiles to prompt the Edit Your Profile dialog box 3 Click Add to enter the name of the profile and then choose Save 4 The new profile will be saved and shown in the Profiles dropdown list box ...

Page 36: ...mediately loaded and displayed on Scanner Properties dialog box To delete a profile 1 From the Image tab dialog box click Profiles to prompt the Edit Your Profile dialog box 2 Choose the profile you want to delete from the dropdown list box 3 Click Delete A Confirm message Are you sure you want to delete this profile is prompted 4 Choose Yes to delete or Cancel to quit ...

Page 37: ...then click the Rename button 3 Enter new name for the profile 4 Choose Save to save the new profile or Cancel to quit Note The preset default profiles include Flatbed Simplex B W 200 dpi Simplex Gray 200 dpi Simplex Color 200 dpi Duplex B W 200 dpi Duplex Gray 200 dpi Duplex Color 200 dpi If you have a simplex or a sheetfed scanner the duplex or the flatbed option will not be available ...

Page 38: ...on your image editing application If your image editing application does not support the type of compression format then either a warning message will appear or the image quality of the compressed file will not be acceptable JPEG Joint Photographic Editor Group This group developed and lent their name to a file compression standard for color and grayscale images that is widely used by scanners and...

Page 39: ...4 18 The Compression tab dialog box ...

Page 40: ... red color watermark or background choose the R Red channel then any red watermark or background will be removed This feature is used to sharpen your text when using OCR Optical Character Recognition software Note that this function supports only black white and gray images Therefore be sure to choose any black white or gray image type while applying this function The Color Dropout dialog box ...

Page 41: ...pped out A lower value will drop more of the selected color out while a higher value will leave more of the selected color in Background Level The pixel which is higher than the background value will be adjusted to the lightest point Adjust the value for both the Filter Threshold and Background Level to produce the best optimal result Example slightly adjusting the background value makes your text...

Page 42: ...User s Manual 4 21 Remove Blue Threshold 20 Background 255 Remove Blue Threshold 20 Background Level 210 ...

Page 43: ...4 22 4 5 The Paper Tab The Paper tab allows you to define values relating to image output i e Auto Crop or not Scan Area OverScan Multi Feed Detection The Paper tab dialog box ...

Page 44: ...ged Use for batches of same sized documents If you select this option you can use the arrow keys to define the x and y offset values width and length to redefine your scanned area The Display window will show image placement as you change the values EOP End of Page Detection This feature allows you to define the area or zone to be imaged Use for batches of same width but different length documents...

Page 45: ...position from the top end of the document to the top end of the scanning area y Width the width of the scanning area y Length the length of the scanning area y Center automatically calculates the x offset for center fed feeding based upon document size selected y relocate the scan area by click the arrow key on the cross sign while retain the scan size View the result from the Display window ...

Page 46: ...User s Manual 4 25 Example Redefine your scan area x offset 2 25 inches y offset 1 13 inches Original After Fixed to Transport Display window Scan Area The Redefined Scan Area ...

Page 47: ...ISO A5 14 8 x 21 cm ISO A6 10 5 x 14 8cm ISO A7 7 4 x 10 5 cm ISO B5 17 6 x 25 cm ISO B6 12 5 x 17 6 cm ISO B7 8 8 x 12 5 cm JIS B5 18 2 x 25 7 cm JIS B6 12 8 x 18 2 cm JIS B7 9 1 x 12 8 cm Scanner Maximum Long Page Long Page When you need to scan documents whose length exceeds scanner maximum please choose Long Page Note if Long Page is selected the Multi Feed Detection will not be available Opti...

Page 48: ...ote the overscan result will not be shown in the Display window and that the availability of the function varies based on type of scanner Multi Feed Detection Multi Feed Detection allows you to detect overlapped document that go through the auto document feeder Multi Feed usually occurs due to stapled documents adhesives on documents or electro statically charged document Note The availability of ...

Page 49: ...ptions available if Multi Feed is detected z Stop Scanning after Multi Feed If this is selected the scanner will stop the feeder if multi feed is detected z Sound Alarm on Multi Feed If this is selected and a wave file is added the scanner will produce a sound alarm if multi feed is detected 2 02 ...

Page 50: ...Click the Browse button on the right side of the speaker icon The Open dialog box appears 2 Choose your wave file 3 Click the Open button The wave file is added Units Defines the primary measurement system Inches Millimeters and Pixels are available ...

Page 51: ...ture appears in a consistent area on the document such as resumes and so on The following procedure describes how to reproduce the entire document in B W and a portion of document picture in color 1 On the Paper tab choose Relative to Document or Fixed to Transport from the Cropping option 2 Choose your scan size from the Scan Area option The selected scan size will be displayed in a red rectangul...

Page 52: ... type from the Image Selection box The selected image will appear in highlighted color For example Front Color 6 Place your cursor on the Preview window and click your left mouse button A cross sign will appear as illustrated Create your relative scan size diagonally by dragging the left mouse button to your preferable size The selected area will appear in a red box as illustrated A black rectangu...

Page 53: ...mage Selection box to scan the entire document 8 Click the Scan button to start scanning the document in two image types and sizes See the result in below The entire document in B W The relative area in color The Relative Area A Cross Sign ...

Page 54: ...User s Manual 4 33 4 6 The Options Tab The Options tab allows you to set following additional image processing settings The Option tab dialog box ...

Page 55: ...ble sided document which are viewed in portrait are sometime fed into the scanner in landscape or vice versa Choice Book Fanfold If Book is selected the image of the reverse side will not be rotated The following illustration shows the documents which should be viewed in portrait are fed into the scanner in landscape ...

Page 56: ...list if you wish to rotate your scanned image Choice None 90 CW clockwise 90 CCW counter clockwise 180 Original Rotate 90 CW Rotate 90 CCW Rotate 180 Blank Page Removal Check if you wish to remove the blank page and move the slider to the left or right to your desired threshold ...

Page 57: ...e or black edge on the border of your scanned image Enter the value from 0 to 5 mm Default value is 0 Original Edge Fill 5mm Black Image Control Option Check the Mirror box if you wish to reverse the right and left side of your image Original The Mirror Effect ...

Page 58: ...your scan background Choice White Background Black Background This option varies based on type of scanner and is available for the front page in the ADF auto document feeder only For the rear page only the white background is available White Background Black Background ...

Page 59: ...lowing settings The Setting tab dialog box Energy Saving Control Check the Enable Energy Saver box and move the slider to the right to set the amount of time to start the energy saver after your last action The range is from 1 to 720 minutes The default is 15 minutes ...

Page 60: ... your scanning task at the fastest speed Page Scan If you choose Page Scan during scanning the scanner will first scan only one page of your document and then send the scanned data to the application and then scan the next page and send the next data to the application and so on Therefore in this mode the scanning speed is slower yet this helps to keep the same scanning progress between the scanne...

Page 61: ...ns the number varies based on type of scanner Please replace the ADF pad and reset the pad count Save Settings after Closing Check to save your scanner properties settings after leaving the dialog box Next time when you open the Scanner Properties dialog box the previously saved settings will be shown ...

Page 62: ...ing system and scanner information The Information tab dialog box The Report button If you encounter any error message while using the scanner click the Report button A report txt file C AVxxx will be generated Please send this file to the nearest service center for trouble shooting ...

Page 63: ...to reset the pad count The Reset Roller Count button After scanning approximately 200 000 pages the number varies based on type of scanner through the ADF the ADF roller may be worn out and you may experience problems with document feeding In this case it is highly recommended to replace the ADF roller with a new one Note the replacement of the ADF roller has to be performed only by authorized ser...

Page 64: ...n modes including B W gray color options Dither 5 halftone levels available can be disabled Dots per inch Select your desired resolution Paper Size Select your desired paper size Brightness Adjust your scan image brightness or darkness Contrast Adjust the range between the darkest and the lightest shades in the image Default Click to reset all settings Area Select your desired scan area or positio...

Page 65: ...User s Manual 6 1 6 Using the Buttons The following picture shows the 3 buttons and 1 function screen on the scanner Function Select Button Scan Button Cancel Stop Button Function Screen ...

Page 66: ...can your document and then link the scanned image to your designated software application All this can be done by a simple touch of the button on the scanner Yet before you scan it is recommended to check the button configurations first to ensure a proper file format and a destination application 6 2 Checking the Button Configurations Before Scanning 1 Click the Scan button on the scanner 2 The Bu...

Page 67: ...g for the file format destination application or other scan settings See Configuring the Button in the subsequent section to reset the settings 4 Click the OK button to leave the window Click to select options or setting The button number and name The file format of the scanned image The options vary based on type of scanner The scan settings for the selected button in this case button 1 The desti...

Page 68: ...plication For example if you want to scan with button 4 which open roxio PhotoSuite and display the scanned image in the main window of roxio PhotoSuite the LED screen should show 4 3 Press the Scan button on scanner 4 After the scanning is finished the roxio PhotoSuite will be launched and the scanned image appears in the main window of roxio PhotoSuite as below Note For details information on ho...

Page 69: ...TENANCE Soak a cotton swab with some isopropyl alcohol 95 Open the document cover as shown below Wipe the document glass by moving the swab from side to side Close the document cover Your scanner is now ready for use 1 1 Document glass ...

Page 70: ... lock to its use position If this is the case pull the scanner status switch to its use position first 2 The scanner is not placed on an even flat desktop surface This may cause the scanner to malfunction Question The scanner is powered on but the lamp does not light up Answer The lamp is probably out of order Contact your local dealer or distributor to replace the lamp For your information the av...

Page 71: ...our printer 2 Adjust the Brightness setting from the TWAIN user interface to get a brighter image Question The scanner works well except for the line art image The lines in the image seem to be much thicker than the original one Answer Increase the Brightness or adjust the Threshold setting to improve line art image Question When I choose optical resolution to be 650 dpi the auto crop and deskew f...

Page 72: ...card interface card etc The name and version of your software application The version of your scanner driver Please call us at US and Canada Area Avision Labs Inc Address 6815 Mowry Ave Newark CA 94560 USA Telephone number 1 510 739 2369 Fax number 1 510 739 6060 Web Site http www avision com E mail support avision labs com Other Area Avision Inc Address No 20 Creation Road I Science Based Industr...

Page 73: ...de 24 bit color 256 shades of gray scale Line Art Error Diffusion Optical Resolution 600 dpi Light Source Cold cathode fluorescent lamp Scanning Document Size 8 5 x 11 69 Interface USB 2 0 Power Requirements 24Vdc 1 25A Power Consumption 36W Operation Temperature 5 C to 35 C Storage Temperature 40 C to 60 C Dimension 288mm x 480mm x 115mm WxDxH Weight 6 38 kgs ...