Configure and Wire Power
Do the following for each V100 in order for the ACM Embedded Controller application to not show an alarm:
1. Place a jumper across and - (22AWG).
2. Place a jumper across AC Fail + and - (22AWG).
3. Place a jumper across Batt Fail + and - (22AWG).
4. Connect the 12VDC +/- to the D8P board (18AWG), as noted below:
l
Connect the Addr 0 V100 12VDC + to Out2+ and - to Out2-.
l
Connect the Addr 1 V100 12VDC + to Out3+ and - to Out3-.
V100
(Addr 0)
Tamper
(Input 5)
-
+
+
-
-
-
+
AC
Fail
(Input 6)
Batt
Fail
(Input 7)
+12VDC
IN
V100
(Addr 1)
Tamper
(Input 5)
+
-
+
+
-
-
-
+
AC
Fail
(Input 6)
Batt
Fail
(Input 7)
+12VDC
IN
D8
OUT
8
7
6
5
4
3
2
1
+
+
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
/05&
For steps below ensure that the card reader, door monitor (if available), request-to-exit (if
available) and lock wiring from the door are fed into the power supply enclosure and route to the
corresponding port on each V100 as desired.
5. If door monitors are available, connect them appropriately to P2\Door Monitor and P5\Door Monitor.
(Refer to the Door Monitor manual.)