EX5000 Release 8.2.2 Installation Manual
- 30 -
5. MFD Feature Setup and Checkout
5.1 Preliminary Test
Power up the MFD for post installation evaluation and configuration. To do so:
1.
Turn on the MFD by applying power to the aircraft electrical bus supplying the MFD.
Note:
Read the appropriate
Pilot’s Guide
for explanations of various functions.
2.
The green LED control lights behind all the front panel controls should light up.
3.
After the initial power up, the software will load and go through several checks. During this startup
sequence the screen displays the text “Initializing-Please Wait...”.
4.
The startup sequence is finished when the “Press any bezel key to Continue...” message
displays.
Figure 6: EX5000 Landscape Front View
5.2 Optional MFD Function Activation Utilities
Avidyne provides the ability to install certain optional functionality using single-use activation utility
disks. This section describes the installation procedure for these utilities.
The Activation Utilities are available for use only by avionics repair facilities performing MFD
installations, MFD software upgrades, and MFD function activation on installed MFD software.
To activate the TAWS, and Broadcast Datalink MFD features:
1.
Obtain the Activation Utility disk for each feature you want to install from Avidyne or an authorized
aircraft manufacturer. Be sure to specify the software part number of the MFD for which you want
to activate a feature.
•
MFD Single-Use TAWS Activation Utility
—This utility activates the MFD TAWS function.
This utility is for use in FAA-approved aircraft repair stations only.
•
MFD Single-Use Broadcast Activation Utility
—This utility activates the MFD Broadcast
Datalink function. This utility is for use in FAA-approved aircraft repair stations only.
These utility disks can be run only once to activate a single function on an MFD. After a single
use they will not run on an MFD.