1/28/19
8
Local 16
This section shows you how to attach the included rack ears to the VENUE | Local 16 I/O rack to mount the rack into a flight case, fur-
niture or other rack housing.
The ears can be installed on the front or the back of the rack depending on the desired orientation. The front of the rack is where all the
I/O connectors are located, and the back of the rack is where the power switches and associated AC connectors are located.
Components
Mounting the Local 16 utilizes the following components:
• (2) Local 16 rack ears
• (6) Rack ear mounting screws (3 per rack ear) and washers
The included rack ears can be installed on the front or the back of the Local 16. The front of the rack is where the status LEDs are located,
and the back of the rack is where the power switches, associated AC connectors, network connectors, and I/O connectors are located.
To attach the rack ears to Local 16:
1
Locate the rack ears and the rack ear mounting screws, included in the Local 16 box.
2
Position one of the rack ears at the front or back of the rack.
3
Using a #2 Phillips screwdriver, insert 3 of the included M4X10 rack ear screws with washers in the positions indicated in the figure
below, and tighten to secure the rack ear to the rack.
4
Repeat for the other side.
Avoid overheating. Be sure to maintain proper air ventilation when installing the device in a rack, and do not block the Local 16 fans
while operating the device.
Attaching rack ears to the front of Local 16