Connecting ISIS Hardware
74
4. Using a laptop (or computer running a Windows operating system), assign a static IP address
of
192.168.0.100
to the network adapter (NIC) and attach it to the management port of left
IXS.
5. Open a browser and navigate to the Switch Agent Web page via the following address:
https://192.168.0.10:5015
.
6. You are asked for the default password. Type
se-admin
.
The Avid ISIS 7500 | 7000 Integrated Switch Blade Window appears.
7. Type the following into the Chassis Configuration window:
-
Starting IP addresses. Enter the IP addresses for both subnets, see
.
-
Subnet mask
-
Ending IP address should be the last address of the engine in the system. Remember that
each engine has 17 IP addresses on each side, for a total of 34. Set the ending address
high enough to cover the last engine and any possible near term future needs.
If you are going to be using a Zone 3 environment you must set the default gateway
addresses for both sides of the engine. These addresses must come from the site’s IS
department.
n
Make sure there are no DHCP servers connected to the network segments that assign addresses
in the Avid ISIS range.
-
Date, Time, and Time Zone or Enable network time protocol
If your network has a network time protocol (NTP) server, you can enter the IP address
of that server in the Chassis Configuration window. NTP Server 1 is for the primary
NTP server and if you have a secondary NTP server, enter the secondary IP address in
NTP Server 2.
n
Once the NTP is configured on a switch, the information propagates to all the other switches
automatically. The time is also automatically synchronized onto the storage blades after the NTP
is configured on the switch.