Rack-Mounting the Equipment
53
Separating the Slide Rails
You need to separate the slide rails and attach the inner “movable” section to the System Director
and the outer “fixed” section to the rack rails.
To separate the slide rails:
1. Slide the slide rail completely open.
2. Press the spring clip on the inner slide rail as shown in the illustration.
n
The blowup of the spring clip shown in the illustration is on the bottom side of the slide rail.
Separating the Slide Rails
3. Pull and separate the two halves.
4. Repeat these steps to separate the second slide rail.
Attaching Inner Slide Rails to the System Director
Attach the inner slide rails that were separated from the outer slide rails to the System Director.
To attach the inner slide rails:
1. Position the inner slide rail against the side of the server so that the screw holes are toward
the rear of the server, and front of the slide rail fits over the tab at the front of the server.
2. Secure the inner slide rail to the server with two of the small screws.
n
You might find more screws in the rail kit than is needed, and described in this procedure.