Software Upgrade
148
12. Update your Avid ISIS client software.
13. Stop both the Active and Standby System Directors.
Copying the Metadata to the New Default Location On the System
Director
The ISIS v4.
x
software is installed in a different path and folders than in previous ISIS releases.
After upgrading your System Director to the ISIS v4.
x
software, you must copy your metadata to
the new location to get access to your existing data.
To copy the existing metadata to the new installation directory:
1. Install the ISIS 7000 v4.x software on your 64-bit System Director as previously described.
2. Stop the System Director Service.
3. Copy the files listed below from their old location and replace the files in the new location
on drive D:
-
Partition0
-
Partition1
-
PartitionDump.bin
Old v2.
x
metadata location
D:\Program Files\Avid Technology\AvidUnityISISSystemDirector
x64
New v4.
x
metadata location
D:\Program Files\Avid\ISIS System Director
4. Start the System Director Service.
n
If there is an error upgrading the metadata, the System Director restarts and then fails again.
Import the metadata as described in the following procedure.
To import the existing metadata to the new installation directory:
1. Start the Avid ISIS and click System Director Control Panel from the Launch Pad or Start >
Programs > Avid > ISIS System Director and select Control Panel.
2. Click Stop System Director.
The Configure File System button becomes active.
3. Click Configure File System.
The File System Configuration dialog box opens.
4. Select Create Active File System From Import and click OK.
5. You are prompted to navigate to the
PartitionDump.bin
file.