![Avery Weigh-Tronix ZQ375 Checkweigher User Instructions Download Page 67](http://html1.mh-extra.com/html/avery-weigh-tronix/zq375-checkweigher/zq375-checkweigher_user-instructions_3030622067.webp)
ZQ375 Checkweigher User Instructions
67
7.1 Supervisor menu for Sim375 application
15.
Press
SELECT
…
no
is displayed.
16.
Press
ZERO
to abort the reset or press
UNITS
…
YES
is displayed.
17.
Press
ZERO
to reset the settings to factory defaults …
rESEt
is displayed.
18.
Press
TARE
…
SEtPnt
is displayed.
7.1.2 Check
Super
Setpoint
Check
1.
From
tArE
press
UNITS
…
chEcK
is displayed. This is the checkweighing configuration item. Under
this you can:
l
Set the outputs to be latched or unlatched
l
Enable output-gross zero band (out-gZb)
l
Set the under and over segment division size
l
Reset all the checkweighing items to factory defaults.
Follow the steps below.
Outputs
Check
Outputs
2.
From
chEcK
, press
SELECT
…
outPutS
is displayed. There are two choices for outputs,
LAtch
and
unLAtch
(default). If you choose
LAtch
, this means that weights will
have to stabilize at or above the output value before the relay or
annunciator changes. If you choose
unLAtch
, the relay and annunciator
will change instantly as the weight swings above and below the output
value.
3.
From
outPutS
, press
SELECT
…
The current choice is displayed.
4.
Press
or
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
outPutS
is displayed.