ZP900 Post Scales User Instructions
31
5.2 RS232 Serial ports default settings
5.2 RS232 Serial ports default settings
5.2.1 For USA
Port 1 is set to SMA protocol @ 9600, 8, none, 1. This allows for connection directly to
the optional ZP900 remote display.
Port 2 is set to NCI protocol @ 9600, 7, even, 1 and ENQ=5. This matches the default
protocol of the NCI 7600 series.
To match the NCI 7800 series may require changing the Port 2 protocol attributes
setting for ENQ to 2. This changes the number of transmitted display digits from 7 to 6
and status bytes from 3 to 2.
For certain software interfaces this may be unnecessary so test the communication
before changing the default settings.
Refer to the ZP900 Service manual for details or contact you scale supplier.
For other countries the default settings for Port 2 may vary.
5.3 USB HID
If enabled the ZP900 USB HID ports will communicate with various Shipping Software
packages. Refer to our website at http://www.averyweigh-tronix.com for a list of which
Shipping Software supports the ZP900 USB HID interface.
5.4 Ethernet
If enabled the ZP900 Ethernet TCP/IP port uses the following default settings:
IP address:
192.168.1.91
Subnet: 255.255.255.0
Gateway: 0.0.0.0
DHCP: OFF
Mode: Server
Port: 10001
Protocol: SMA