36
ZM400 Series Indicators Service Manual
5
Diagnostics level menus
5.1.6 Inputs
1.
Press
SELECT
…
in 000
is displayed, if no inputs are jumpered.
2.
To test input 1, jumper pins 1 and 2 of the I/O connector on the indicator …
The first digit becomes
1
until the jumper is removed.
3.
To test input 2, jumper pins 1 and 3 of the I/O connector on the indicator …
The second digit becomes
2
until the jumper is removed.
4.
To test input 3, jumper pins 1 and 4 of the I/O connector on the indicator ….
The third digit becomes
3
until the jumper is removed.
5.
Press
ZERO
…
inPutS
is displayed.
5.1.7 Outputs
1.
With
outPutS
is displayed, press
SELECT
…
outPut1
is displayed.
2.
Press
SELECT
…
o.1-oFF
is displayed.
Inputs
Test
configured
inputs
inPutS
The input test is used to verify if external switches wired
to the input ports on TB2 are functioning properly.
Follow the steps below to perform the inputs test.
CAUTION: Be sure to take proper precautions to ensure material controlled by
the scale outputs will not create a hazardous condition during an output test.
Outputs
1
2
3
Toggles
selected
output
on and off
outPutS
The output test is used to verify if external relays or
lights (etc.) connected to TB2 are properly wired
and functioning properly.
Follow the steps below to perform the output test.