![Avery Weigh-Tronix M3060 User Instructions Download Page 19](http://html.mh-extra.com/html/avery-weigh-tronix/m3060/m3060_user-instructions_3030575019.webp)
M3060 User Instructions
19
3.4 Power Connections - Battery
1.
Loosely connect the scale interface cable to the
SCALE
connector on the
indicator.
Figure 3.8 Scale Connector
2.
Run the cable from the indicator to the junction box, allowing some slack in the
cable.
3.
Connect the other end of the scale interface cable to the junction box.
4.
Inspect the cable run and make sure that the cable is not pinched, kinked or in
the way of moving parts or sharp objects.
5.
Tuck or cable tie the excess cable along the run as necessary.
6.
Tighten the connector at the indicator.
3.4 Power Connections - Battery
Power Connector
Pin
Description
1
+12 VDC
2
Ground
3
Output #1
4
Input #1
Available Power Cables
Part Number
Description
50474-0028
10 ft. power cable
50474-0036
20 ft. power cable
50474-0042
30 ft. power cable
To indicator
To power
Figure 3.9 Power Connector, Battery Cable
1.
Disconnect the negative wire from the battery terminal before performing any
electrical work.
2.
Loosely attach the connector end of the power cable to the M3060 indicator.
Scale Connector
Pin
Description
1
+ Excitation
2
- Bridge
3
+ Bridge
4
- Excitation