60 Series User Instructions
29
3.2 Parts Counting
The counting parameter must be enabled before using. Follow the instructions below
for sampling and counting parts. A new sample must be performed for each unique part
being counted. The indicator will not store the average piece weight.
3.2.1 Simple keypad sample (model 460)
Method 1: Sample 10 pieces (parts) and count additional parts
1.
Press [SELECT] until Qty is displayed.
2.
Place the empty container on platform (optional). If a container is not being
used, skip this step and go to step 3.
3.
Press the [TARE] key. The model 460 indicator will tare to a zero net weight.
4.
Place 10 parts on the platform.
5.
Press [TARE] to accept the sample.
6.
Add additional parts to be counted. This number of parts added will be
displayed.
Method 2: Sample and count a specific number of parts
1.
Press [SELECT] until Qty is displayed.
2.
Place the empty container on platform (optional). If a container is not being
used, skip this step and go to step 3.
3.
Press the [TARE] key. The model 460 indicator will tare to a zero net weight.
4.
Place the specified number of parts on the scale. (
Add XX
, "XX" being the
number of parts to sample) or key in the number of parts being sampled by
pressing the [PRINT] key until the first digit is displayed. Use the [UNITS] key
to move to the next digit. Continue using the [PRINT] and [UNITS] keys until
the desired sample size is displayed and press [TARE].
5.
Press [TARE] to accept the sample. (Or add any number of parts, key in the
number added, then press [TARE]).
Method 3: Sample and count with a known container weight
1.
Press [SELECT] until Qty is displayed.
2.
Place the full container of parts on the weigh platform.
3.
Press the [TARE] key.
4.
The indicator will tare to a zero net weight. The display shows the current net
weight and prompts
Add 10
5.
Remove the specified number of parts from the container.
6.
Press [TARE].
7.
The indicator calculates the piece weight of the sample parts removed.
Summary of Contents for GSE 460
Page 10: ...8 60 Series User Instructions 1 9 Declaration of Conformancy ...
Page 11: ...60 Series User Instructions 9 ...
Page 12: ...10 60 Series User Instructions ...
Page 13: ...60 Series User Instructions 11 ...
Page 25: ...60 Series User Instructions 23 2 1 4 663 Big box outline drawing 2 1 5 665 Outline drawing ...
Page 46: ......
Page 47: ...31 WI 150 Ultra Low Power Weight Indicator Service Manual ...